(1) Up to cat.3/PLd (EN ISO 13849-1)
(2) Up to cat.4/PLe (EN ISO 13849-1)
(3) Up to SIL2 (IEC/EN 61508)
(4) Up to SIL3 (IEC/EN 61508)
(5) Deactivate test pulses, cross-circuit detection by plausibility (cross comparison) of
NC/NO contacts at the inputs. Activation simultaneity recommended.
(6) Deactivate the test pulse, no cross-circuit detection possible. Sensor cables may
need to be protected and laid separately so that fault elimination according to
DIN EN ISO 13849-2, table D.4 can be applied. Activation simultaneity recommended.
(7) For sensor variants not listed here, the achievable safety level is identical to that
listed above, according to the respective contact variant of the sensor (only working
open contacts).
3.
Product-specific information
3.1.
Electrical data
Electrical data
Switching voltage U
1)
Safety contact switching current I
- without LED
- with LED (green)
- with LED (green)
Control contact switching current
Series resistor safety contact
- without LED
- with LED (green)
Series resistor control contact
Max. voltage drop additionally for LED U
Max. frequency of operating cycles
Max. rated insulation voltage U
Rated impulse withstand voltage U
Degree of pollution
Usage category
Type key actuator
Standard actuator
Amplified actuator for larger operating distances
Secured operating distance
Standard
Reinforced
Safe distance for switching off
Standard
18.01.2024
Max.
IMax.
d
i
imp
2)
S
ao
2)
S
ar
153MSKx0x1x
24 V DC +/- 20 %
200 mA (-25°C to +80°C)
10 mA (-25°C to +70°C)
5 mA (-25°C to +80°C)
10 Ω (0.75 W)
10 Ω (0,10 W)
10 Ω (0,25 W)
300 V DC / 250 V AC
153MSK.0.1.
153MBK001 /
153MBK201
153MBK101 /
153MBK301
end face 4 mm
side 4 mm
end face 8 mm /
side 4 mm
end face 10 mm
side 10 mm
V2.0
Product-specific information
165MSK00x1x
50 mA
3.7 V
5 Hz
0.8 kV
3
DC 12
165MSK00.1.
165MBK001 /
165MBK201
165MBK101 /
165MBK301
end face 5 mm
side 5 mm
end face 8 mm
side 8 mm
end face 14 mm
side 14 mm