Descargar Imprimir esta página

Dalbach KSG122-F Instrucciones De Uso página 37

Frigorífico empotrable de una puerta

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 58
9.4 Hazards due to refrigerant
HEALTH HAZARD!
If the refrigeration circuit is damaged, refrigerant R600a will escape. The refrigerant
poses a health hazard on contact with the eyes and if inhaled.
FLAMMABLE GAS!
EXPLOSION AND FIRE RISK!
The refrigeration circuit of the appliance contains the refrigerant isobutane (R600a), a
natural gas with high environmental compatibility; it is flammable.
Only authorised specialists are allowed to work on the refrigerant system.
Do not damage the refrigeration circuit, e.g. by puncturing the refrigerant
channels with sharp objects, kinking the pipework, etc.
Do not damage any parts of the refrigeration circuit when transporting, setting
up, servicing or disposing of the appliance.
In order that an explosive gas/air mixture cannot form in the event of a leak in
the refrigeration circuit, the room in which the appliance is installed must have a
minimum size according to standard EN 378 of 1 m³ per 8 g of refrigerant. The
quantity of refrigerant in the refrigerating appliance can be found on the type
plate.
What to do if the refrigeration circuit is damaged:
✓ Avoid naked flames and ignition sources.
✓ Ventilate the room in which the appliance is installed thoroughly.
✓ Contact After Sales Service.
EN
Page | 37

Publicidad

loading