CLEANING
Do not over tighten the lid lock ring.
1. Firstly, via the air bleed screw located on top of the domed lid, release any
built up pressure within the tank. Unscrew the domed filter lid using the two
convenient moulded handles from the filter tank.
2. Remove the cartridge element from the filter tank.
3. Using a garden type hose clean the surface of the pleated elements, Making
sure to clean between the pleats.
4. Place the cartridge back into the filter tank ensuring that it is seated.
5. Ensure lid "O"-ring is correctly re-installed.
6. Place domed lid onto tank and screw the tight using the two moulded handles.
7. Refer to the start up procedure to re-commence operation.
It is suggested that you should periodically remove the cartridge filter element and soak it over night in a suitable
cartridge cleaning compound. This will remove any debris not removed by hosing down of the element.
The cleaning time depends upon the swimming pool condition and use. Intervals between cleaning the element
should not exceed a period of 12 months in any instance.