Shutting down the engine
To turn off the engine, follow the procedure below:
01 - Release the throttle trigger.
02 - Leave the engine idling for a few moments.
03 - Set the stop button to the "Off" (O) position.
Pulverization
Make sure the boom register is closed before starting the engine.
Once the engine is warmed up, turn the throttle lever to the highest speed position and open the liquid
valve.
Open the boom register in case the chemical is not entering, even if the motor speed is increased and
the unit is operated at that speed for 1 minute.
If the problem persists, refer to the "Troubleshooting" section.
Increase the motor speed when a nozzle with a high discharge rate is used and reduce the speed when
a low discharge nozzle is used.
Run the unit at motor speeds high enough to allow for effective spraying.
01 - Prepare the chemical mixture according to the manufacturer's specifications.
02 - Set the pressure regulator to minimum.
03 - Start the engine, following the information in this manual.
04 - Adjust the pressure as desired.
05 - Point the nozzle of the lance at the area to be sprayed.
06 - Press the lever to starting the spraying.
07 - Release the lever to stop the spraying.
Positions of lever:
Released (Closed)
Attention! When you have finished spraying, spray clean water through the nozzle for a few
minutes for cleaning. Wipe off the liquid chemical in the machine after use.
Attention! Pay attention to the level of syrup, preventing the pump from running for a long time
without liquid, which can damage the equipment.
Attention! If you have any doubts about this adjustment, contact an Authorized Service Center.
59
Pressed - (Open)