Technical data
Performances: air at 26°C / water at 26°C / humidity at 80 %
Operating power (max-min speed)
Consumed power (max-min speed)
COP (max-min speed)
Technical specifications
Operating temperature
Operating pressure
Power supply
Admissible variation in voltage
Hydraulic connections
Type of refrigerant fluid
Protection rating
Frequency bands
Radiofrequency emission power
Installation location
Technical specifications
Nominal operating power
Max operating power
Minimum cable section*
Acoustic power (max-min)
Acoustic pressure at 10m (max-min)
Recommended water flow
Refrigerant fluid load
Approximate weight
* Values provided for information purposes for a maximum length of 20 metres (calculation base: NFC15-100), must be
checked and adapted to theinstallation conditions and standards of the installation country.
Eco Elyo-05 Eco Elyo-07 Eco Elyo-09 Eco Elyo-13 Eco Elyo-15 Eco Elyo-20
kW
5.5 - 1,5
7 - 2
kW
0,9 - 0,1
1.1 - 0.15
6.1 - 14.4
6.5 - 13.4
Air
Water
Refrigerant
Water
GHz
dBm
Eco Elyo-05 Eco Elyo-07 Eco Elyo-09 Eco Elyo-13 Eco Elyo-15 Eco Elyo-20
A
4.9
A
8
mm²
dB(A)
59-47
dB(A)
28-16
m³/h
3
kg
0.3
Tonn CO2
0.20
eq.
kg
38.5
9.5 - 2.3
13 - 2.4
1.4 - 0.2
2 - 0.1
6.7 - 13.5
6.5 - 16.4
-5 to 43°C
In "heating mode" from 15 to 40°C
In "cooling mode" from 8 to 28°C
from 0,5 to 42 bar (from 0.05 to 4.2 MPa)
from 0 to 2 bar (from 0 to 0.2 MPa)
220 - 240V ~ / 1 phase / 50-60 Hz
± 6 % (during operation)
2 PVC Unions Ø 50
R32
IPX4
2.400 - 2.497
+19.5
Outdoors
6.3
9
3 x 2,5
64-51
33-20
4
0.45
0.30
41.5
❺
Characteristics
15 - 2.5
20 - 2.8
2.5 - 0.15
3.3 - 0.2
6 - 16.3
6.2 - 16.5
8
10.2
13.6
13
16
19
3 x 4
67-55
70-57
36-24
39-26
5
6
0.6
0.7
1.0
0.41
0.47
0.68
46
52.5
66
7