Descargar Imprimir esta página

Xylem JABSCO Quiet Flush 37245 Serie Manual De Instrucciones página 2

Inodoro eléctrico

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 24
FEATURES
• Very quiet flush cycle - like a household toilet
• Single button flush actuator - with dual function waterlevel
control switch
• Supplied with Par-Max 3 self-priming pump to provide sea
water or lake water to rinse the toilet bowl
• White vitreous china bowl available in compact or comfortable
household size
• Baked enamel seat & cover, soft close seat option available on
regular bowl models
• High capacity waste macerator and bowl discharge pump
SPECIFICATIONS
Ports:
Water consumption:
VARIATIONS
Model Number
37245-3092
Compact Bowl 12V
37245-3094
Compact Bowl 24V
37245-4092
Regular Bowl 12V
37245-4192
Regular Bowl 12V, Soft Close Seat/Lid
37245-4094
Regular Bowl 24V
37245-4194
Regular Bowl 24V, Soft Close Seat/Lid
OPERATION
The Quiet-Flush toilet provides both quiet operation and user con-
trol of water levels in the toilet bowl. A single large push-button
switch provides a simple flush mode by activating both the rinse
water supply and the macerator discharge pump simultaneously.
An additional rocker switch offers independent control of the rinse
water supply and discharge pump separately so the bowl water
level can be easily raised or lowered by the user. This provides
a method of minimizing water use, when desired, as well as a
means of raising the water level in the bowl when appropriate for
user comfort. It also allows for complete evacuation of the bowl
water while underway in rough sea conditions.
INSTALLATION
The 37245-Series Quiet Flush Toilet is complete with a dedicated
Par-Max 3 pump to provide either sea or lake water to rinse
the toilet bowl when flushing the toilet. This pump is intended
to be located remotely from the toilet but will function best if
the distance from the toilet is kept to a minimum. Because it is
self-priming, it may be located above the vessel's waterline. It
must be installed with the Pumpgard strainer (provided with the-
toilet) located somewhere in the inlet plumbing to the pump. The
toilet also includes a multi-function flush control which should be
installed in a bulkhead location that is convenient to the toilet and
allows access for wiring to run from the power source and to both
the toilet discharge pump and the Par-Max rinse water pump.
Model 37245—Series
Par-Max 3 pump and toilet inlet
3/4"hose barb outlet 1" hose barb
Water1-2 quarts (litres)/flush
Description
Install the toilet seat and lid assembly on the china bowl with the
fasteners provided and position the toilet in its desired location.
When locating the toilet, ensure there is adequate clearance
above and to the rear of the bowl sothe seat and lid assembly can
rotate slightly past vertical so it will remain up when lifted. It is
all right to rotate the waste pump assembly under the china bowl
to provide clearance from possible obstructions, if desired. This
can be accomplished by removing the four white plastic hex head
caps from the nuts at the base of the china bowl and removing the
four machine screws and nuts that secure the china bowl to the
base. The base can then be reattached to the bowl at any position
in 90º increments. Once the exact position for the toilet has
been determined, mark the location of the four base attachment
holes on the toilet mounting surface. Determine the best toilet
attachment method using 5/16"(8 mm) fasteners (either machine
screws for through bolting or lag screws for topside attachment)
and drill the appropriate size holes for the fasteners being used. If
securing the toilet with lag screws into a plywood underlayment
below fiberglass, be sure to drill a hole through just the fiberglass
layer large enough to allow clearance for the screw threads and
shank to avoid cracking the fiberglass.
The Par-Max pump should be mounted to a solid mounting
surface above the water-line in a dry area with adequate ventila-
tion. It should be secured with four fasteners through the rubber
grommets that snap into the pump's base. Do not over-tighten
the mounting screws and crush the grommets such that they will
not absorb vibration. The pump may be mounted horizontally,
or if vertically, with the pumphead facing down. Plumbing runs
should be kept as short and straight as possible. All plumbing
should be completed with quality 3/4"(19 mm) hose that will not
collapse or kink. Route the inlet hose from a 3/4"(19 mm) through
hull and seacock fitting located well below the waterline (and well
forward of any discharge through hulls, if installed) to the pump
inlet port. Ensure the inlet hose passes through an accessible
location (preferably above the vessel's waterline) that will allow
for the installation of the Toilet Pumpgard strainer where it can be
periodically inspected and cleaned of debris.
2