Descargar Imprimir esta página

SATA SATAjet 1000 B Instrucciones De Servicio página 34

Ocultar thumbs Ver también para SATAjet 1000 B:

Publicidad

Idiomas disponibles

Idiomas disponibles

Operating Instructions SATAjet 1000 B (RP/HVLP)
EN
■ Remove spring and paint needle [7-3].
■ Unscrew the air cap [7-1].
■ Screw fluid tip [7-2] out of the gun body using the universal spanner.
Mount the nozzle set
■ Screw fluid tip [7-5] into gun body using universal spanner and tighten
with a torque of 14 Nm.
■ Screw air cap [7-4] onto gun body.
■ Insert paint needle and spring [7-6].
■ Screw adjusting screw [1-3] with counter nut [1-4] into the gun body.
After installation, adjust the material flow according to chapter 7.2.
8.2. Replacing the air distribution ring
Notice!
After disassembly of the air regulator ring, check the sealing surface in
the spray gun. If any damages are detected, contact the SATA customer
service department (the address is found in chapter 16).
Dismantle the air distribution ring
■ Dismantle nozzle set (see chapter 8.1).
■ Remove the air distribution ring using the SATA extraction tool [8-1].
■ Check sealing surface [8-2] for soiling, clean if necessary.
Mount the air distribution ring
■ Insert air distribution ring. The pin [8-3] of the air distribution ring must
be aligned accordingly.
■ Press the air distribution ring in evenly.
■ Mount nozzle set (see chapter 8.1).
After installation, adjust the material flow according to chapter 7.2.
8.3. Replace paint needle seal
This must be replaced when material leaks from the self-adjusting paint
needle packing.
Dismantle paint needle seal
■ Loosen counter nut [1-4].
■ Screw adjusting screw [1-3] with counter nut out of the gun body.
■ Remove spring and paint needle [9-1].
■ Remove the trigger guard [9-2].
■ Screw the paint needle seal [9-3] out of the gun body.
Mount paint needle seal
34

Publicidad

loading