Malfunction
Spray gun drips at flu-
id tip ("fluid tip cone").
11. Disposal
Dispose of the completely emptied spray gun as a recyclable material.
To avoid damage to the environment, dispose of the spray material and
release agent separately from the spray gun in an appropriate manner.
Comply with local regulations!
12. After Sale Service
Accessories, spare parts and technical support may be obtained from
your SATA dealer.
13. Accessories
Art. No.
3988
6981
27771
64030
53090
48173
14. Spare Parts
Art. No.
1826
3988
6395
9050
15438
16162
40
Cause
Contamination be-
tween paint needle tip
and fluid tip.
Damaged nozzle set.
Description
Paint strainer
Quick coupling nipple G ¼ " (female thread)
Air micrometer 0 – 845 with pressure gauge
SATA cleaning set
Air hose
High performance grease
Description
Drip-stop for 0.6 l plastic cup
Paint strainer
CCS clip (green, blue, red, black)
Tool kit
Paint needle sealing
Swivel joint G ¼ " (male thread)
Corrective action
Clean fluid tip and paint
needle. Heed cleaning
instructions (see chap-
ter 9).
Replace nozzle set (see
chapter 8.1).