- Select TIG welding mode with 2 Times torch mode (when TIG and 2T LEDs are on), with 4 Times torch mode
(when TIG and 4T LEDs are on) or with SPOT mode (when TIG and SPOT LEDs are on) on mode selector 4
(Fig.11).
Item
Parameter
2 - Fig.
11
4 - Fig.
12
SLOPE
1 - Fig.
DOWN
12
SLOPE
2 - Fig.
POST
12
3 - Fig.
SPOT
12
I
Adjust the welding current LED 2 - Fig.11 by means of the left knob
2
3 (Fig.11). During welding, this parameter is continuously active (by
turning the left knob (Fig.11), the welding current is adjusted.
UP
Set the UP SLOPE time in seconds by pressing the right knob 6
(Fig.11) until LED 4 (Fig.12) lights up.
Set the DOWN SLOPE time (current ramp down for crater
treatment) in seconds by pressing the right button 6 (Fig.11) until
LED 1 lights up (Fig.12).
Set the POST GAS time (gas flow after welding, which protects the
GAS
weld bead from oxidation and cools the torch) in seconds by
pressing the right button 6 (Fig. 11) until LED 2 (Fig. 2) lights up.
See following chapters
Description
Fig.11
Fig.12