Product description
2 PRODUCT DESCRIPTION
Various models of pumps are described in these
operating instructions. Identify your model from
the identification plate.
2.1
Product overview
No.
Component
1
Connection cable with mains plug
2
Handle
3
Float switch cable
4
Pump housing
5
Float switch
6
Suction slots
7
Connection elbow
8
Combination adapter
9
Venting (Drain 10000/ 15000 INOX/
Drain 20000 HD only)
2.2
Function of DRAIN 10000 / 12000
The pump draws the conveying medium through
the suction slots directly and feeds it to the pump
outlet at the combination nipple. It is switched on
and off using a float switch.
2.3
Function of DRAIN 10000 INOX / 15000
INOX / DRAIN 20000 HD
The pump draws the pumped medium directly
through the suction slots and feeds it to the pump
outlet. It is switched on and off using a float
switch. In order to operate properly, the pump
must be vented at the vent.
2.4
INOX (stainless steel)
Pumps with the designation "INOX" are made of
stainless steel. This does not affect their design
or function.
2.5
Thermal protection
The pump is equipped with a thermal protection
switch which switches off the motor in the event
of overheating. After a cooling down period of ap-
prox. 15 - 20 minutes, the pump switches on
again automatically.
Operate the pump only when it is fully immersed.
2.6
Intended use
The pump is intended for private use in house
and garden. It may only be operated within the
467771_k
framework of the operating limits indicated in the
technical data.
The pump is suitable for:
Water removal in the event of a flood
Re-pumping and pumping out from vessels
(e.g. swimming pools)
Water removal from streams and shafts
Water removal from drains and trickle shafts.
The pump is suitable only for conveying the fol-
lowing fluids:
Clear water, rainwater
Chlorinated water (e.g. swimming pool water)
Waste water
Dirty water with max. 5% suspended matter
and a grain size of max. 30 mm diameter.
with pump DRAIN 20000 HD of max. 38
mm
Any use not in accordance with this designated
use shall be regarded as misuse.
2.7
Possible misuse
The pump must not be operated continuously. It
is not suitable for conveying:
Drinking water
Salt water
Foodstuffs
aggressive media, chemicals
corrosive, flammable, explosive or fuming flu-
ids
fluids that are hotter than 35 °C
water containing sand and abrasive fluids.
3 SAFETY INSTRUCTIONS
DANGER! Danger from contact with live
parts! A defect in the pump or the extension ca-
ble can result in serious injury!
Disconnect the connector plug from the
mains immediately.
Connect the device via an earth leakage cir-
cuit breaker with a rated leakage current of
< 30 mA.
WARNING! Risk of injury. Defective and
disabled safety and protective devices can result
in serious injury.
Have any defective safety and protective de-
vices repaired.
Never disable safety and protective devices.