Descargar Imprimir esta página

Zodiac Z260IQ Manual De Instalación Y De Uso página 35

Ocultar thumbs Ver también para Z260IQ:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 123
• Install the unit outdoors. Do not insall the unit indoors or in a closed and unventilated
area.
• The appliance shall be stored in a room without continuously operating ignition
sources (for example: open flames, an operating gas appliance or an operating
electric heater).
• The device must be stored so as to prevent mechanical damage from occurring
• Be aware that R290 refrigerant may not contain an odour.
• Do not use means to accelerate the defrosing process or to clean, other than those
recommended by the manufacturer.
• Do not piece or burn.
INSTALLATION AND MAINTENANCE
• Our products may only be assembled and installed in pools compliant with
standards IEC/HD 60364-7-702 and required national rules. The installation should
follow standard IEC/HD 60364-7-702 and required national rules for swimming
pools. Consult your local dealer for more information.
• The appliance may not be installed close to combustible materials, or the air duct
inlet of an adjacent building.
• Do not install in one environment which has operating or potential ignition sources.
• In the event of a leak, escaping refrigerant may mix with air to form a flammable
atmosphere. There is a risk of fire and explosion.
• Only carry out the work if you are competent and have knowledge about the special
features and risks of R290 refrigerant.
• During installation, troubleshooting and maintenance, pipes may not be used as
steps: the pipe could break under the weight, spilling coolant and possibly causing
serious burns.
• When servicing the appliance, the composition and state of the heat transfer fluid
must be checked, as well as the absence of any traces of coolant.
• During the appliance's annual sealing test in accordance with applicable legislation,
the high and low pressure switches must be checked to ensure that they are
securely fastened to the cooling circuit and that they cut off the electrical circuit
when tripped.
• During maintenance work, ensure there are no traces of corrosion or oil around
the cooling components.
• Before beginning work on the cooling circuit, stop the appliance and wait for a few
minutes before fitting the temperature and pressure sensors. Some elements such
as the compressor and piping may reach temperatures in excess of 100°C and high
pressures with the consequent risk of severe burns.
TROUBLESHOOTING
• All brazing must be carried out by qualified brazers.
• Replacement pipes must always be made of copper in compliance with standard
EN 12735-1.
• Leak detection; pressure test:
- never use oxygen or dry air (risk of fire or explosion)
- use dry nitrogen or the mixture of nitrogen and refrigerant indicated on the
information plate,
- the test pressure for both the high and low pressure circuits must not exceed 42
bar in cases where pressure gauges are connected to the appliance.
• The high pressure circuit pipes are made of copper and have a diameter equal to or
greater than 1''5/8. A certificate as indicated in §2.1 in compliance with standard EN
10204 must be requested from the supplier and filed in the installation's technical
file.
• Technical data relative to the safety requirements of the various applicable directives
are indicated on the information plate. All this information must be recorded in the
appliance's installation manual, which must be kept in its technical file: model, code,
serial number, maximum and minimum OT, OP, year of manufacture, CE marking,
3

Publicidad

loading