Descargar Imprimir esta página

Zodiac Z260IQ Manual De Instalación Y De Uso página 45

Ocultar thumbs Ver también para Z260IQ:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 123
2.2 I User interface presentation
REGULATION (ELECTRONIC CONTROLLER)
Heating /Auto/
Cooling mode
Set time (clock)
Setpoint water
temperature
Set temperature
Parameters
Water temperature
SET (setpoint water
temperature /
parameters)
Start-up and Locking
2.2.1 Mode details
Press
3s to unlock the control box.
Press
2s to turn the heat pump on or off. This button is also used to return to the main interface.
Icons
The lock activates automatically after 60 seconds of inactivity). When the cabinet is locked, the logo
Operating Modes
Press the button
to change the operating mode:
Then press
to change the operating mode press
again to validate the change and return to the main
menu.
ECO Heating mode:
theheat pump operates silently.
SMART Heating mode:
AUTO
theheatpumptooperate in a conventional manner
BOOSTheating mode:
that the heat pump quickly heats the water in your pool.
Automode:Theheat pump intelligently chooses the most
appropriateoperating mode according to the setpoint temperature.
SILENTCoolingmode:Choose this cooling mode for
theheat pump to operate silently.
ECO Cooling mode:
the heat pump operates in a conventional manner.
BOOST Cooling mode:
theheatpump to operate in a classic way.
13
Lock
Error
Browse/
Validate/
Return
Return
Mode
ECOSILENCE
Heating
SMART
BOOST
Choose this heating mode so that
Heating/
SMART
Cooling
Choose this heating mode for
(recommended mode)
Choose this heating mode so
ECOSILENCE
Cooling
SMART
BOOST
Choose this cooling mode so that
Choose this cooling mode for
Current time
Defrosting :
(clock)
process for the good operation of the
heat pump
Wi-Fi
Timer On/Off
Inverter mode
SMART, Right: BOOST)
Water inlet temp
Compressor running
Fan running
Filtration pump running
These 3 icons can be off if heating/
cooling is not needed (normal
behaviour)
Browse
Description
Reduced power to further energys savings and lowest
noise level. Best to maintain the temperature when
Setting the required temperature
outside air temperature is warm.
Step 1: Go to the main menu
Automatic power adjustment depending on the need.
Chooses between ECOSILENCE and BOOST modes
by unlocking the control panel.
automatically.
Step 2: Press the
Maximum power for fast heat-up. Best at the beginning
of the season to rise up the temperature or to maintain
buttons to change the set
the temperature when the outside temperature is cold.
temperature.
The heat pump intelligently chooses the most
appropriate operating mode according to the setpoint
Clock setting
temperature.
Step 1: Go to the main menu
by unlocking the control panel.
Cooling the pool at reduced power to further energys
savings and lowest noise level.
Step 2: Press
enter
Automatic power adjustment depending on the need.
Chooses between ECOSILENCE and BOOST modes
The clock display flashes.
automatically.
Step 3: Press
hours to minutes and validate by
Cooling the pool at maximum power for fast cooling.
pressing
.
Step 4: Change hours/minutes by using
Step 5: Press the button
and return to the main menu.
- 24 -
automatic and mandatory
Deforsting
(left: ECOSILENCE, middle:
appears.
and
2 times to
the clock setting interface.
to switch from
and
.
1s to confirm the setting

Publicidad

loading