Descargar Imprimir esta página

Roger Technology B70/1DCHP Instrucciones Y Advertencias Para El Instalador página 57

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 144
CONTACT
25(AP)
23(COM)
26(CH)
23(COM)
27(PP)
23(COM)
28(PED)
23(COM)
29(+24V)
30(COM)
31(LAM)
30(COM)
ENC
FC
SB
RECEIVER CARD
BATTERY CHARGER
B71/BCHP
BATTERY KIT
2x12V
4,5 Ah
Only AGM type
Version HW 02:
adds voltage limiter,
only for High Speed and
Reversible versions
WIFI
DESCRIPTION
Open control signal input (N.O.).
IMPORTANT: persistent activation of the opening command prevents automatic reclosure; the auto-
matic reclosure time count is resumed when the opening command is released.
Close command input (N.O.).
Step by step mode command input (N.O.).
The function of the control is determined by parameter
Partial open control signal input (N.O.).
Set by default to 50% of completely open position.
Power feed for external devices. See technical characteristics.
Connecting B72/BRAKE/2 power unit for BG30 High Speed versions.
(24V
Connector for connecting to encoder installed on motor.
WARNING! Always disconnect from electrical power before disconnecting or connecting the encoder
cable. N.B.: Ready wired in factory by ROGER TECHNOLOGY.
Connector (N.C. contacts) for connecting mechanical limit switch (see
netic limit switch (see
Adjust the limit switches so that, once triggered, the gate stops slightly before it reaches the me-
chanical stop. IMPORTANT: repeat the travel acquisition procedure after each adjustment to the
limit switches.
N.B.: Ready wired in factory by ROGER TECHNOLOGY.
Connector (N.C.) for connecting release contact. If the motor release handle is opened, the gate
stops and no command signals are accepted.
Once the release handle is closed again and the key turned to the close position, if the gate is in an
intermediate position, the control unit initiates the position recovery procedure (see chapter 20).
N.B.: Ready wired in factory by ROGER TECHNOLOGY.
Connector for plug-in radio receiver board.
The control unit has two radio remote control functions by default:
The programming buttons PR1 and PR2
Connector for slot-in battery charger board.
In the event of a mains power loss, the controller unit is powered by the batteries. When battery
power is used, the message
at intervals until mains power is restored or until the battery voltage drops below the minimum
permissible limit. In this case,
accepts no commands.
If mains power is lost while the gate is moving, the gate stops and then automatically resumes the
interrupted manoeuvre after 2 seconds.
To reduce battery consumption, the positive power feed wire of the photocell transmitters may be
connected to terminal SC
unit disconnects power from the accessory devices when the gate is completely open or completely
closed.
WARNING! the batteries must always be connected to the electronic controller unit in order to char-
ge. Periodically (at least every 6 months), check that the battery is in good working order.
For more information, refer to the installation manual for the B71/BCHP battery charger.
In the B70/1DCHP control units for High Speed and Reversible motors, the B72/CL voltage limiter
device is added (by Roger Technology).
In case you need the battery charger, for High Speed motors it must have version HW 02, as it
integrates this limiter.
Connector for B74/BCONNECT WiFi IP device.
This IP device allows, using any internet browser, the complete management of the control panel
both in proximity (point-to-point connection) and via cloud (remote connection).
.
- duty cycle 50%).
.
- detail C). The gate stops when the limit switch is activated.
(Battery Low) is shown on the display and the controller unit
or
,
- detail B) or mag-
57

Publicidad

loading