Setting photocell mode during gate opening (FT2)
DISABLED. Photocell is not active or not installed.
STOP. The gate stops and remains stationary until the next command is received.
IMMEDIATE REVERSE. The gate reverses immediately if the photocell is activated during gate opening.
TEMPORARY STOP. The gate stops as long as the photocell is obstructed. The gate resumed opening when the photocell
is cleared.
DELAYED REVERSE. The gate stops if the photocell is obstructed. The gate closes when the photocell is cleared.
Setting photocell mode during gate closing (FT2)
DISABLED. Photocell is not active or not installed.
STOP. The gate stops and remains stationary until the next command is received.
IMMEDIATE REVERSE. The gate reverses immediately if the photocell is activated during gate closure.
TEMPORARY STOP. The gate stops as long as the photocell is obstructed. The gate resumed closing when the photocell
is cleared.
DELAYED REVERSE. The gate stops if the photocell is obstructed. The gate opens when the photocell is cleared.
Photocell (FT2) mode with gate closed
This parameter is not visible if
,
or
is set.
If the photocell is obstructed, the gate cannot open.
The gate opens when an open command is received, even if the photocell is obstructed.
The photocell sends the gate open command when obstructed.
Enable close command 6 s after activation of photocell (FT1-FT2)
N.B.: This parameter is not visible if
or
is set. NOTE: in the case of photocells being blanked during
opening, the 6 secs. count starts when the wings are completely open.
Disabled.
Enabled. When the photocell barrier FT1 is crossed, a close command is sent 6 seconds later.
Enabled. When the photocell barrier FT2 is crossed, a close command is sent 6 seconds later.
Setting motor stop distance
= faster deceleration/shorter stop distance ...
= slower deceleration/longer stop distance.
Maximum stroke length selection
Maximum length 20 metres
Maximum length 25 metres
Selecting installation position of motor relative to gate (seen from interior side)
NB:
PROG key until
appears on the display, then repeat the acquisition procedure (see chapter 11.2).
N.B.: in the event of a reset to restore the default parameters, this parameter must be set again manually.
Motor installed on left.
Motor installed on right.
COS1
Sensing edge NOT INSTALLED.
NC contact (normally closed). The gate reverses only when opening.
Contact with 8k2 resistor. The gate reverses only when opening.
NC contact (normally closed). The gate always reverses.
Contact with 8k2 resistor. The gate always reverses.
Management of two 8k2 sensitive edges connected in parallel (total resistance 4k1). The gate reverses only when
opening.
Management of two 8k2 sensitive edges connected in parallel (total resistance 4k1). The gate always reverses.
69