6. TROUBLESHOOTING
DANGER! Risk of physical injury!
Injury when the product starts accidentally.
v Disconnect the product from the mains before you
troubleshoot the product.
To clean the pedestal and the impeller [ Fig. T1 / T2 ]:
If the pedestal cannot be changed according to the chapter
3. OPERATION To change the function mode, the pedestal must
be cleaned.
1. Unscrew the 4 Phillips screws
2. Pull the suction base
(9)
off the pump.
3. Unscrew the 4 Phillips screws
4. Pull the pedestal
(7)
off the suction base
(7)
5. Clean the pedestal
, the suction base
(the warranty does not become void as a result of this maintenance
work).
6. Clean the sealings
(14)
carefully to avoid damage and leakage.
7. Reassemble the pedestal
Make sure that the 4 springs
(7)
estal
.
A damaged seal must be replaced.
For safety reasons a damaged impeller can only be exchanged
by the GARDENA Service Centre.
Problem
Possible Cause
Pump is running, but
Air cannot escape, because
doesn't deliver water
the pressure line is closed.
(Possible kink in the pressure
hose.)
Air in suction foot.
Suction opening is clogged.
Hose is clogged.
Impeller is blocked.
Water level below minimum
water level when put into
operation.
Pump does not start or
Thermal switch has turned
stops suddenly during
the pump off because of over-
operation
heating.
Pumping without electricity.
RCD has triggered (residual
current).
Pump is running but
Suction opening is clogged.
the delivery drops
suddenly
The pump sucks to the ground
(e. g. foil).
Hose is clogged.
Pedestal is not correctly
Pedestal is dirty.
locked in position.
Pedestial is stuck
Button is stuck
Button is dirty.
NOTE: For any other malfunctions please contact the GARDENA service
department. Repairs must only be done by GARDENA service departments
or specialist dealers approved by GARDENA.
7. TECHNICAL DATA
Submersible Pump
Unit
Rated power
W
Mains voltage
V (AC)
GAR_09048-20.960.02_2024-01-09.indd 11
GAR_09048-20.960.02_2024-01-09.indd 11
(8)
.
(10)
.
(9)
.
(9)
(11)
and the impeller
(7)
(9)
and the suction base
in reverse order.
(12)
are fitted on the domes
(15)
of the ped-
Remedy
v Open the pressure line
(e. g. shut-off valve, delivery
units).
v Wait for about 3 minutes
until the pump has vented;
if necessary, turn off and
then on again.
v Clean the suction opening
with a water jet.
v Remove the clog from the
hose.
v Clean the pedestal and the
impeller.
v Submerge the pump deeper.
v Clean the suction opening.
Observe the max. media
temperature (35 °C).
v Check fuses and electrical
plug connections.
v Disconnect the pump
and contact the GARDENA
Service.
v Clean the suction opening
with a water jet.
v Place the pump on a suitable
hard ground.
v Remove the clog from the
hose.
v Clean the pedestal and
the impeller.
v Clean the button.
Value (Art. 9048)
550
230
Submersible Pump
Unit
Value (Art. 9048)
Mains frequency
Hz
50
Max. delivery capacity
l/h
15,000
Max. pressure /
bar /
0.7 /
Max. delivery head
m
7.0
Max. submersion depth
m
7
Min. cut-in height
clear water / dirty water
mm
300 / 340
(approx.)
Max. cut-in height
clear water / dirty water
mm
500 / 550
(approx.)
Min. cut-out height
clear water / dirty water
mm
90 / 120
(approx.)
Max. cut-out height
clear water / dirty water
mm
150 / 200
(approx.)
Residual water level
clear water / dirty water
mm
1 / 35
(approx.)
Dirty water with
max. particle diameter
clear water / dirty water
mm
5 / 35
Minimum water depth for
operation
clear water / dirty water
mm
10 / 45
(approx.)
Power cable
m
10 (H05RN-F)
Weight without cable
kg
4.9
(approx.)
Connection thread water
Inch
G 1 1/2"
outlet
25 mm (1")
mm /
32 mm (1 1/4")
Connection options
(Inch)
38 mm (1 1/2")
33,3 mm G 1"
Max. media temperature
°C
35
Note: The switch on / switch-off heights and the minimum water level on start-up were calculated
without the height differences to be negotiated. Pump heads of approx. 1 m or more may result in
longer suction times of up to 1 minute, or higher minimum water levels of up to + 5 cm.
8. ACCESSORIES
GARDENA Flat Hose Set
10 m 38 mm (1 1/2") hose with hose clamp.
GARDENA Hose Clamp
For 25 mm (1") hoses via the connection nipple.
GARDENA Hose Clamp
For 32 mm (1 1/4") hoses via the connection nipple.
GARDENA Hose Clamp
For 38 mm (1 1/2") hoses via the connection nipple.
GARDENA Pump Connection
For 19 mm (3/4") hoses via the GARDENA Connection
Set
System.
9. WARRANTY / SERVICE
9.1 Product registration:
Please register your product at gardena.com/registration.
9.2 Service:
Please find the current contact information of our service on the back
page and online:
• United Kingdom:
https://www.gardena.com/uk/support/advice/contact/
• Australia:
https://www.gardena.com/au/support/advice/contact/
• New Zealand:
https://www.gardena.com/nz/support/advice/contact/
• South Africa:
https://www.gardena.com/za/support/contact/
Art. 5005
Art. 7193
Art. 7194
Art. 7195
Art. 1752
11
09.01.24 14:29
09.01.24 14:29

Publicidad

loading

Este manual también es adecuado para:

9048