Descargar Imprimir esta página

Gardena 15000 Libro De Instrucciones página 9

Bomba sumergible para agua limpia/agua residual
Ocultar thumbs Ver también para 15000:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 37
Automatic venting
This pump is equipped with a vent valve which eliminates any air pockets in the
pump. Depending on the function, a small amount of water can escape from the
side of the housing.
Additional safety warnings
Electrical safety
DANGER! Cardiac arrest!
This product makes an electromagnetic field while it operates. This
field may under some conditions interfere with active or passive medical
implants. To decrease the risk of conditions that can possibly injure or
kill, we recommend persons with medical implants to speak with their
physician and the medical implant manufacturer before you operate the
product.
Cables
If extension cables are used, these must comply with the minimum cross-
sections in the table below:
Voltage
Cable length
230 – 240 V / 50 Hz
Up to 20 m
230 – 240 V / 50 Hz
20 – 50 m
DANGER! Electric shock!
With a cut off mains plug, moisture can get into electrical parts via the
mains cable and cause a short circuit.
v Never cut the mains plug off (e. g. to feed through wall).
v Don't use the power cable for plugging off.
v If the supply cord is damaged, it must be replaced by the manufacturer, its
service agent or similarly qualified persons in order to avoid a hazard.
Mains plug and extension connections must be protected from water splashes.
Ensure that the electrical connections for plugs and sockets are made in areas
safe from flooding.
Protect the mains plug and the mains power cable from heat, oil and sharp
edges.
Observe the mains voltage. The information on the nameplate must be in agree-
ment with the data for the mains power grid.
The pump's mains plug must be disconnected before anybody enters the swim-
ming pool or touching the surface of the water.
The mains power cable must not be used for fastening or transporting the pump.
For submerging or lifting / securing the pump, please use a fastening rope. Do not
use the power cable to lift the pump.
Please regularly check the connecting line.
Before using, always subject the pump (especially the power cables and the
power connections) to a visual inspection.
A pump which is damaged should not be used. In the event of damage, have the
pump checked by GARDENA Service.
Assembly instructions: Retighten all screws by hand.
Before use after maintenance, make sure that all parts are screwed together.
When using our pumps with a generator, the warnings of the generator manu-
facturer must be observed.
Personal safety
DANGER! Risk of suffocation!
Small parts can be easily swallowed. There is also a risk that the poly-
bag can suffocate toddlers. Keep toddlers away when you assemble the
product.
Please be sure not to use the clear water function to pump dirty water. It can lead
to blockage and overheating of the pump.
Observe the minimum water level in accordance with the characteristics given for
the pump.
Allow the pump to run no longer than 10 minutes against a closed pressure side.
Sand and other abrasive substances cause increased wear and reduce the
pump's output.
The float switch may only be operated outside the water.
The hose must not be disconnected during operation.
Allow the pump to cool down before troubleshooting.
2. ASSEMBLY
DANGER! Risk of physical injury!
Injury when the product starts accidentally.
v Disconnect the product from the mains before you assemble
the product.
To remove the handle lock [ Fig. A6 ]:
(C)
The handle lock
must be removed before the product is used for the
first time.
GAR_09048-20.960.02_2024-01-09.indd 9
GAR_09048-20.960.02_2024-01-09.indd 9
1. Pull the attached handle locks
2. Keep them for later securing procedures (e. g. transport or storage).
Connection possibilities of the connection nipple [ Fig. A1 ]:
The hose can be connected via the connection nipple
hose diameters or the GARDENA Connection System.
Large hose diameter
GARDENA Connection System
Small hose diameter
When using the largest hose diameter, the pump has the maximum
delivery capacity.
Pump
Small hose diameter
Art. GARDENA Hose Clamp
Medium hose diameter
Art. GARDENA Hose Clamp
Cross section
Large hose diameter
1.5 mm
2
Art. GARDENA Hose Clamp
2.5 mm
2
When using the 38 mm (1 1/2") hose, we recommend the GARDENA Flat
Hose Set Art. 5005 with 10 m hose and hose clamp.
* There is an additional connection nipple
To connect the hose via the connection nipple:
1. When using the large diameter hose, cut off the connection nipple
at
(a)
2. Push the hose onto the connection nipple
3. Fix the hose to the connection nipple
Clamp.
Connect hose via the GARDENA Connection System:
19 mm (3/4") / 15 mm (5/8") and 13 mm (1/2") hoses can be connected
via the GARDENA Connection System.
We do not recommend hose diameters smaller than 25 mm (1"), otherwise
there will be a significant reduction in the output of the delivery rate.
Hose diameter
13 mm (1/2")
15 mm (5/8")
19 mm (3/4")
1. Cut off the connection nipple
2. Connect the hose to the connection nipple
GARDENA Connection System.
To assemble the pump connection [ Fig. A5 ]:
v Operate the pump only with the elbow connector.
The hose can be easily connected and disconnected using the locking
devices
1. Screw the elbow connector
(If the hose is to be installed horizontally, the elbow connector
screwed out again up to half a turn.)
2. Screw the connection piece
3. Push the connection nipple
until it stops and it engages audibly and visibly.
The hose is securely connected to the pump.
3. OPERATION
v Disconnect the product from the mains before you connect,
adjust or transport the product.
To pump water:
If the pump cannot be immersed via the handle, the pump must always
be immersed via a rope
(C)
outwards.
Cut off nipple at
Cut off nipple at
Do not cut off nipple [ Fig. A4 ]
Art. 9048
25 mm (1")
Art. 7193
GARDENA Connection System G 1"
* 32 mm (1 1/4") Art. 7194
38 mm (1 1/2")
Art. 7195
ß
4a
.
(4)
Pump connection
GARDENA Pump Connection Set
GARDENA Pump Connection Set
GARDENA Pump Connection Set
(4)
at
(b)
.
DANGER! Risk of physical injury!
Cut injury by the impeller.
(2)
on the elbow connector
(1)
.
(1)
clockwise into the pump until it stops.
(3)
into the connection nipple
(4)
of the hose into the elbow connector
DANGER! Risk of physical injury!
Injury when the product starts accidentally.
ß
[ Fig. O1 ].
R
(4)
with different
(a)
[ Fig. A2 ]
(b)
[ Fig. A3 ]
for 1 1/4" hoses is supplied.
(4)
(4)
.
e. g. with a GARDENA Hose
Art. 1750
Art. 1750
Art. 1752
(4)
via the appropriate
(1)
can be
(4)
.
(1)
9
09.01.24 14:29
09.01.24 14:29

Publicidad

loading

Este manual también es adecuado para:

9048