Descargar Imprimir esta página

Johnson COCI90PBB Manual De Instrucciones página 38

Publicidad

Idiomas disponibles

Idiomas disponibles

Gas connection
Any work on the gas equipment and systems should be performed by the
authorized and competent persons
Prior to installation, check that the local supply conditions (gas type and gas
pressure) are compliant with the product settings
LPG connection
Be careful that the gas hose and gas valve you use for your oven should be safe.
Attach the gas supply hose at the hose end behind the oven and tighten by
means of clips and screw (Figure 6). Make sure it is tightened.
Gas hose of the oven should be me longer than 1500mm.
Pressure of the valve to be used for LPG should be 30 mbar- 300mmSS and
certificated.
Do not use an adjustable pressure reducing valve.
Gas supply hose should not pass through the hot section behind the oven.
Temperature of the gas hose should not exceed 90°C.
Prior to use, make sure the system is gastight.
NG (natural gas) connection
If your equipment is set for natural gas, you should have it connected by an installer
registered with the natural gas distribution company. Natural gas connection of your
equipment is 1/2".
If you desire to convert your equipment from LPG to natural gas or from natural gas to
LPG, please call the nearest service center for gas conversion settings.
1-
G1/2 Nipple (union)
2-
Silicone gasket
3-
G1/2 Hose inlet (gas inlet)
4-
Metal clamp
5-
Gas hose (inner diameter 8mm )
Figure 6
1-
G1/2 Nipple (union )
2-
Silicone gasket
3-
G1/2 NG hose ( natural gas hose as per EN 14800)
12
V.1

Publicidad

loading

Este manual también es adecuado para:

Coci90pbx