Descargar Imprimir esta página

KRATOS SAFETY KS LINE KS 4000 Manual Del Usuario página 54

Línea de vida horizontal

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 89
FA 60 216 90
The FA 60 216 90 intermediate corner piece can be fitted:
Onto FA 60 211 30/C/D and FA 60 211 50/C/D posts using an M12 x 45
mm bolt and an M12 washer (provided with the posts). This component can
be fitted onto either of the two holes located on the sides of the shoulder
at the top of the post.
To a concrete floor using 3 chemical or mechanical anchors (one in the
middle and 2 at the ends).
FA 60 202 00
The FA 60 202 00 energy absorber attaches to the end piece with a shackle.
Make sure the shackle tightening screw head faces upwards. Apply some
thread lock. Insert the split pin and lock it.
FA 60 203 00
Place the seal ring on the cable, then introduce the cable into the FA 60 203
00 crimped tensioner sleeve. At least 100 mm of cable must be fed into
the tube. Mark the cable to check the length introduced into the tube. If the
length measured is the minimum length required, reintroduce the cable into
the tube. Using the crimping tool, start crimping at point 1 by positioning
the crimper jaws in the centre of the crimp markers on the tensioner.
Continue crimping in the direction indicated on the drawing until you have
finished crimp No. 6. Rotate the crimping tube by 45° between crimps to
prevent it from becoming deformed over its length. Refer to the crimping
machine user instructions before commencing. When you have finished
crimping, apply coloured lacquer to the cable and tube which will act as an
indicator in case the cable slips inside the tube.
Particular care must be taken when carrying out this operation as it cannot
be reversed and it is central to the strength of the system and the safety
of its users.
Unscrew both ends of the tensioner. Take care not to exceed the maximum
permitted opening distance (508 mm) of the tensioner by distributing the
length equally between the ends of the tensioner body; this equates to
approximately 50 mm of visible thread either side of the tensioner body
(distance X). Fit the FA 60 203 00 tensioner to the FA 60 202 00 absorber
using the shackle. Make sure the shackle tightening screw head faces
upwards. Apply some thread lock. Insert the split pin and lock it.
ENERGY ABSORBER
TENSIONER
54
X ≤ 50 mm
x
x

Publicidad

loading