SEEN FROM THE TOP
Warning. -
Any installa on should be done by an authorised installer. A faulty installa on of this
product, and an inadequate maintenance might cause grave incidents.
3. OPERATION
3. 1 Combustion
For good combustion that is clean and environment-friendly (CO-free), when the wood is well lit and it
has reached a high temperature, you must close the primary air inlet and keep the secondary air inlet
open. This will let the air for combustion (preheated) enter through the top of the fireplace next to the
glass and through the back wall below the deflector to ensure better gas combustion. You will notice this
in an increase in flames and temperature.
Wood burners and inserts are intermittent combustion appliances. This means that they should be lit,
loaded with an approximate weight of fuel as recommended by the manufacturer for each model,
followed by a full combustion cycle and fuel reloads after each combustion cycle.
Good combustion is necessary for optimum performance and a better view of the flames through the
glass.
Guidelines:
Maintain a high and constant temperature in the fireplace. Accordingly, the fireplace door must be
closed at all times and opened only to load firewood, which must be done as quickly as possible.
Keeping the door open will cause the stove to cool down, it will worsen the combustion and make
lighting of the new wood more difficult.
Do not take a long time when loading firewood and wait for the end of the combustion cycle, when the
flames of the previous load disappear.
Warning. – During the use of your stove or inset appliance, the high temperatures generated during
combus on and cooling down of the device a erwards will cause expansion and contrac on of the steel
plates. This may cause some metallic sounds; these are completely normal and should not be considered a
defect in the product.
A full combustion cycle comprises the following:
1. A short period after reloading when the wood begins to heat up without flames. The time until the
flame lights is an indication of the fireplace temperature. If you wait too long to reload firewood, the
18
EXPANSION JOINT
MIN. 0'5cm.
EXPANSION JOINT
MIN. 1cm.
SEEN FROM THE SIDE