EXTERIOR OR IN-LINE BLOWER SELECTION
CAUTION: Either an exterior blower or in-line blower may be used with this hood.
The WM24E hood must be installed with blower models EB6, EB9, EB12, EB15,
ILB3, ILB6, ILB9, or ILB11 only. Other Blowers cannot be substituted (Blowers sold
separately).
The blower must be UL listed for Canadian and U.S. use, and evaluated for use with
solid state speed control, rated 120V, 60 Hz, 6.0 A max.
INSTALL THE DUCTWORK
NOTE: To reduce the risk of fire, use only
metal ductwork.
1. Choose the location where the Exterior
or In-Line Blower will be mounted. See
illustrations below for mounting location
suggestions and restrictions.
2. A straight, short duct run will allow the
hood to perform most efficiently.
3. Long duct runs, elbows and transitions
will reduce the performance of the hood.
Use as few of them as possible. Larger
ducting may be required for best
performance with long duct runs.
4. After the Exterior or In-Line Blower has
been installed, connect round metal
ductwork and work back towards the
hood location. Use duct tape to seal
joints between ductwork sections.
5. An 8" round to 10" round transition (Model
414) is required. For best air performance,
install the transition as close to the range
hood as possible.
DUCTWORK ON THE CEILING
10" ROUND
DUCT
8" ROUND
DUCT
4-3/4"
HOOD
23-3/8" TO 30" ABOVE
COOKING SURFACE
EXTERIOR
BLOWER
8" TO 10"
ROUND
TRANSITION
8-1/8"
1-1/4"
- 8 -
EXTERIOR BLOWER
SUGGESTED MOUNTING LOCATIONS
OK
OK
CAUTION: MAY NOT FIT
UNDER EAVES OF SINGLE
STORY HOMES
DUCTWORK ON THE WALL
8-5/16"
HOOD
23-3/8" TO 30" ABOVE
COOKING SURFACE
8" TO 10"
ROUND
TRANSITION
EXTERIOR
BLOWER
10"
ROUND
DUCT