Condenser And Tubing Requirements - Scotsman C1448R Manual De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

C1448, C1848, C2148
Remote Condenser Models - Installation Manual

Condenser and Tubing Requirements

Dimensions (cm)
w x d x h
122 x 61 x 74
same
same
Table notes: Medium cube models have the same
electrical characteristics as Small. Series revision
code omitted. All the listed condensers include a
headmaster valve.
*Ratings include the remote condenser motor, as it
is designed to be powered by the ice machine. If
connecting remote condenser independently of the
ice machine, use the information on the
condenser's dataplate for fuse and wire sizes.
Model
Electrical
C1448MR-6
230/50/1
C1848MR-6
230/50/1
C2148MR-6
230/50/1
June 2007
Use condenser
ERC311-6
ERC611-6
ERC611-6
Precharged tubing kits:
The ice making head's and the remote condenser's
refrigeration circuits must be connected. They are
designed to be connected using precharged
refrigerant tubing, supplied in kits of liquid and
discharge tubes. Several lengths are available,
order the one that just exceeds the length needed
for the site.
10'
C1448,
C1848,
RTE10
C2148
No additional refrigerant is required.
Page 4
Maximum Fuse
Size*
30
30
30
20'
40'
75'
RTE20
RTE40
RTE75

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

C1848rC2148r

Tabla de contenido