Installation: Product Specifications

Location Limitations
This ice system is made up of three parts, the ice
making machine, or head; the remote condenser;
and the interconnecting tubing. The ice making
machine must be installed indoors, in a controlled
environment. Space must be provided near the
machine for service access. The remote condenser
may be installed above or below the ice machine,
per the limits stated later in this manual. The
remote condenser may be installed outdoors within
the temperature limits listed below. The
interconnecting tubing must be installed per the
directions stated in this manual, and the amount of
tubing exposed to uncontrolled temperatures must
be minimized.
Space Limitations
Although the machine will function with no
clearance to the top and sides, some space must
be allowed for service access. Building the
machine in with no access will cause higher service
cost, in many cases this extra cost may not be
covered by warranty.
Environmental Limitations, ice machine:
Minimum
o
Air temperature
10
C.
Water
o
4
C.
temperature
Water pressure
1 bar
Remote condenser
Minimum
o
Air temperature
-6
C.
Power Supply
230 volt model
Power Cord Reference Table
Rated Current of Model
3,1 through 6 amperes
6,1 through 10 amperes
10,1 through 16
amperes
16,1 through 25
amperes
Warranty Information
The warranty statement for this product is provided
separately from this manual. Refer to it for
applicable coverage. In general warranty covers
defects in material and workmanship. It does not
cover maintenance, corrections to installations, or
Maximum
situations when the ice machine is operated in
o
38
C.
circumstances that exceed the limitations printed
above.
o
38
C.
Product Information
5 bar
The machine is a specialized version of a modular
cuber. A modular cuber does not include any ice
storage, it is designed to be placed onto an ice
storage bin. Many installations only require the
Maximum
matching bin, but some may need an adapter to be
o
49
C.
placed between the ice machine and the bin.
Additionally, the machine must be connected to the
correct remote condenser and use the correct
pre-charged tubing. The machine is supplied with a
full refrigerant charge, field charging is not
required.
This product cannot be stacked. See the chart for
application information.
June 2007
Page 2
Minimum
Maximum
207 volts
253 volts
Nominal
Cross-Sectional
2
Area (mm
) of
Conductors
,75
1,0
1,5
2,5

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

C1848rC2148r