BFT LINEA 1 Instrucciones De Uso Y De Instalacion página 6

Automatizaciones para puertas
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 44
ENGLISH
4) FUNCTIONS WHICH CAN BE CONFIGURED BY MEANS OF PFD
MOD. FUNCTION SELECTOR (fig. 2)
4.1) General outline on PFD mod. selector (optional)
The PFD model pushbutton panel allow the following operations to be car-
ried out on the LINEA door:
• Selection, by means of appropriate key, of the required door function.
This means that, when a key is pressed, the door selects the function
connected with that key and, after confirmation is given, the door is posi-
tioned in the set state.
• Activation of function selection after entering the secret code. This is a
five-figure code, called the user code.
4.2) User functions of the PFD mod. selector
WARNING! To access the user functions you need to enter the code.
If you do not wish to enter the code, open the J1 (Fig.28A) jumper
inside the PFD function selector: in this case the desired function can
be set by pressing the relevant push-button directly for 2 seconds.
To confirm the settings and exit from the user menu, press T6 or wait
until the 5-second time-out has elapsed.
• USER CODE
This is used to access the user menu.
Press T6 and keep it pressed for at least 5 seconds. If the internal J1 jum-
per is closed, the red LEDs start to blink. Enter the user code (5 figures),
keeping in mind that T1=1, T2=2, T3=3, T4=4, and T5=5. The factory-preset
code is 12345. Each time a figure is entered, a green LED lights up (from
the top down). After entering the correct PIN, the orange L12 LED lights up
and stops the blinking.
At this point, select the required function by pressing T1,T2,T3 orT4. Then
press T6 to confirm the settings and exit the user menu (a confirmation
beep is emitted).
When all the LEDs are switched off, except for the L10 LED, which indicates
correct system operation, the door is managed by both radar controls and
opens completely.
• DOOR CLOSED IN THE DAY
The door closes and stays closed. The antipanic function remains active. It
only the key-opening commands are accepted for the door to open.
•DOOR CLOSED AT NIGHT
The door closes and stays closed. The antipanic function is not active. It
only accepts the key-opening command.
When the manual key-opening command is activated by means of the key
selector, the door opens and stays open for the clearance time set. After
this access time has elapsed, the door returns to the state preset by the
PFD selector.
•DOOR TOTALLY OPENED
The door opens running at approaching speed (slowly) and stays comple-
tely open.
• DOOR PARTIALLY OPENED (except for ELA version)
The door opens and stays partially open; its opening dimension can be
set.
• PARTIAL OPENING (except for ELA version)
Partial opening during normal operation (winter).
• CHEMIST'S OPENING (except for ELA version)
6 -
LINEA 1-2 - Ver. 02
USER'S MANUAL
The door opens by the width set for chemist's opening (only works with
manual opening pushbutton which, when the door is open, also controls
closing). The automatic closing operation is excluded.
•INTERNAL RADAR
It only activates the internal radar. The door opens when detecting one-way
transit.
•SECURITY DOOR RADAR
It activates the security door function.
•RESET
IIf you keep the key pressed for approximately 3 seconds and then release
it, you reset the default configuration, and exit from the user's menu.
If you do not execute any operation within the 10 seconds following the
entry of the user code, you come out of the user menu.
4.5) Modification of user code on PFD mod. selector
The user code must only be modified by a qualified person (installer).
WARNING: After activation, during the initial manoeuvres the door ac-
quires a map of the safety parameters. In this sensitivity calibration
phase, a beep is emitted.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Linea 2

Tabla de contenido