nected load of the vacuum cleaner's
socket outlet P
A
Please also observe the operating
instructions and safety warnings of
the power tool being connected to
the socket outlet of the vacuum
cleaner.
Recommendation: Always operate
the vacuum cleaner via a residual
current device (RCD) with a rated
residual current of 30 mA or less.
The vacuum cleaner may only be
stored indoors.
The allowable ambient temperature
when vacuuming is –10 °C to +40 °C.
Using the vacuum cleaner at low
temperatures is not permitted. At
low temperatures, the mains cable
can become damaged and thus
impair the safety.
Operating Instructions.
Operation, see page 11/12.
An adequate ventilation rate L must
be provided for when the outgoing
air is circulated. The circulated air-
flow must not exceed 50 % (max.)
of the fresh air volume (room vol-
ume x ventilation rate L
lowing applies without special
ventilation measures:
-1
L
= 1 h
.
w
In case of a short-circuit and/or
heavy discharge of dust, switch the
vacuum cleaner off immediately and
disconnect it from the power supply.
Do not use the vacuum cleaner
as a step or stepladder. If the
vacuum cleaner tips over, you
could injure yourself or damage the
vacuum cleaner.
.
). The fol-
w
Flat-fold filter
Changing the filter, see page 13–15/
38 Section "Fault Finding."
Wear personal protective equip-
ment (respiratory mask, protective
gloves) when changing the filter.
The filter may only be changed in
rooms suitable for this, where other
persons are not at hazard.
After removing the contaminated
filter, clean the clean-gas side and the
sealing surfaces using commercially
available, non-scouring cleaning
agents and water.
CAUTION
fold filter, as otherwise the motor
will become damaged and increased
output of fine dust may pose a haz-
ard to one's health.
For vacuuming dusts of dust
category L or M, only dry flat-
fold filters may be used that never
were moist nor wet.
Before switching from wet to
dry vacuuming, allow the flat-
fold filter to dry or replace through a
dry one. Otherwise, the flat-fold fil-
ter will become unusable.
Keep the flat-fold filter dry and clean
it regularly.
Disposal bag, fleece filter bag
(see page 8)
Only for FEIN Dustex 35 MX AC (**):
For vacuuming fine dust and for low-
dust disposal, a disposal bag or fleece
filter bag must additionally be used.
When inserting, work the disposal
bag over the container rim. Pull the
other opening of the disposal bag
completely over the collar of the
vacuum socket.
en
Never vacuum
without the flat-
35