en
38
should be cleaned in order to pre-
vent any risks.
The room/enclosure in which the
vacuum cleaner is disassembled
should be well ventilated. Wear per-
sonal protective equipment during
maintenance. After the maintenance,
the maintenance area should be
cleaned.
Products that have come into contact
with asbestos may not be sent in for
repair. Dispose of products contam-
Fault Finding.
Malfunction
Vacuum cleaner can-
not be switched on.
Reduced vacuuming
capacity.
Dust escapes during
vacuuming.
No suction capacity
when wet vacuuming.
The automatic shut-off
(while wet vacuuming)
does not respond.
inated with asbestos according to the
applicable country-specific regula-
tions for such disposal.
The current spare parts list for this
vacuum cleaner can be viewed on
the Internet at www.fein.com.
If required, you can change the
following parts yourself:
Fleece filter bag, disposal bag, flat-
fold filter, hose, tool adapter, elbow,
vacuum tubes, crevice nozzle, floor
nozzle, bristle lips, rubber lips, step
adapter, vacuum brushes
Cause
Circuit breaker of
power connection
has tripped.
Vacuum cleaner in
remote control oper-
ation.
Vacuum cleaner not
fitted correctly.
Vacuum system
clogged.
Fleece filter bag full.
Flat-fold filter full.
Disposal bag full.
Incorrect installation
position of
flat-fold filter
Container full.
Sensors soiled/ dirty. Clean sensors and space in
Container full.
Troubleshooting
Ensure power supply.
Set operating-mode selec-
tor switch to "I".
Mount vacuum cleaner lid
properly and completely
close both fasteners.
Clean vacuum hose and
extension tubes.
Replace fleece filter bag.
Replace flat-fold filter.
Replace disposal bag.
Correct installation position
of flat-fold filter.
Empty container.
between with a brush.
For electrically non-con-
ductive liquids, check filling
level and empty container,
as required.