Descargar Imprimir esta página

DeWalt DXAEPIP3W Manual De Instrucciones página 15

Inversor de la energía de 1000 vatios y 3 vías

Publicidad

Idiomas disponibles

Idiomas disponibles

This indicates a thermal fault condition.
The Digital Readout shows "0W". The
fault icon will flash. Refer to the following
section for an explanation. One of the
Input LED Indicator light solid depending
on the power source input.
This indicates an overload or short circuit
fault condition. The Digital Readout shows
"0W". The fault icon will flash. Refer to
the following section for an explanation.
One of the Input LED Indicator light solid
depending on the power source input.
Installation
Your inverter will provide you with continuous electrical power when
powered by a reliable 12 volt DC source, such as a vehicle battery or
a multiple battery configuration, or a DeWALT® 20V Battery Pack. This
manual does not describe all of the possible configurations.
Mounting the Inverter
Tools Required: four BA4x14 screws in a set and Philips head
screwdriver (NOT supplied).
The inverter comes equipped with mounting brackets for long-term
installation. The manufacturer recommends using BA4x14 screws
in a set with a standard Philips head screwdriver (none of these are
supplied). User may choose to use different screws appropriate to the
mounting surface.
Secure the inverter to a flat surface, observing all cautions regarding
installation found in this manual.
CAUTION – To avoid the risk of property damage: Only mount the
inverter on a level, stable surface, assuring that all screws are tightened
securely and observing all of the cautions and recommendations
regarding installation found in this manual.
Operating Environment
For best operating results, your inverter should be placed on a flat
surface, such as the ground, car floor or seat, or other solid surface
to help diffuse the heat that is generated. Position the inverter as close
to the DC power source as possible.
The inverter should only be operated in locations that meet the following
criteria:
DRY – Do not allow water and/or other liquids to come into contact
with the inverter.
COOL – Surrounding air temperature should ideally be 50-68°F (10-
20°C). Do not place the inverter on or near a heating vent or any piece
of equipment that is generating heat above room temperature. Keep
the inverter out of direct sunlight.
VENTILATED – Allow at least three inches of clearance from other
objects to ensure free air circulation around the inverter. Never place
items on or over the inverter during operation.
SAFE – Do not locate inverters in an area, room or compartment
where explosives or flammable fumes might be present, such as
engine rooms, engine compartments, and boats or small, unvented
battery compartments.
Connecting the Inverter
The inverter must be connected only to batteries with a nominal output
voltage of 12 volts when it is powered through the battery clamps or
12VDC adapter plug. The unit will not operate from a 6 volt battery
and will sustain permanent damage if connected to a 24 volt battery.
The inverter also can be powered through a DeWALT® 20V Battery
Pack.
The standard North American 120 volt AC Outlets and USB charging
ports allow simultaneous operation of multiple devices. Simply plug the
14

Publicidad

loading