2. Identify the positive (+) and negative (–) DC power source (battery)
terminals.
3. Install a fuse holder or breaker close to the positive (+) terminal of
the DC source (battery).
4. Connect a length of wire on one side of the fuse holder or circuit
breaker. Connect the other end of the wire to the positive (+)
terminal of the inverter.
5. Connect a length of wire between the inverter's negative (–) terminal
and the DC power source negative (–) terminal.
6. Connect a short length of wire to the other terminal of the fuse
holder or circuit breaker. Mark it "positive" or "+".
7. Connect the free end of the fuse or breaker wire to the positive (+)
terminal of the DC power source (battery).
8. Insert a fuse appropriate to the inverter in the fuse holder.
9. Check to make sure the power button is turned off.
10. Make sure that all connections between cables and terminals are
secure.
11. Press and hold the power button for one second to turn the
inverter on. A beep will sound, the backlit LCD and the Battery
Clamps Input LED Indicator will activate to indicate the inverter is
operating properly and the 120 volt AC Outlets are ready to power
appliances that draw up to 1000W continuous. The USB outlets
are turned on as well. Refer to "Power and Fault Indicators on the
LCD Display" for an explanation of the operating and fault icons.
If a fault icon appears, refer to the "Protective Features" section
and the "Troubleshooting" section of this manual.
12. Test the inverter by turning it on and plugging in a 100 watt lamp
or equipment. If the inverter is not operating properly, then refer to
the "Protective Features" section and the "Troubleshooting" section
of this manual.
CAUTIONS
• The cable and fuse sizes given here are a general recommendation.
You should always consult your National Electrical Code prior to
beginning each specific installation.
• Loose connectors may cause overheated wires and melted insulation.
• Check to make sure you have not reversed the polarity. Damage due
to reversed polarity is not covered by our warranty.
Important Cable Information: Substantial power loss and reduced
battery operating time results from inverters installed with cables that are
not able to supply full power. Symptoms of low battery power can result
from cables that are either excessively long or an insufficient gauge.
Connecting to a Power Source Using a
DeWALT® 20V battery pack (not included)
(up to 300W only)
1. Make sure no battery clamps or 12 Volt DC Adapter Plug connected
to the unit.
2. Insert the DeWALT® 20V battery pack to the Battery Pack Terminal
Connector on the unit.
3. Press and hold the power button for one second to turn the inverter
on. A beep will sound, the backlit LCD and the DeWALT® 20V Battery
Pack Input LED Indicator will activate to indicate the inverter is operating
properly and the 120 volt AC Outlets are ready to power appliances that
draw up to 275W continuous. The USB outlets are turned on as well.
Notes:
• Refer to "Power and Fault Indicators on the LCD Display" for an
explanation of the operating and fault icons. If a fault icon appears,
refer to the "Protective Features" section and the "Troubleshooting"
section of this manual.
• Ensure that the wattage of all equipment simultaneously plugged into
the inverter does not exceed 275 watts continuous.