Filter drum
5. Manually turn the filter drum by one whole rotation to ensure unobstructed movement.
6. Fill the filter with water until the rinsing pump is submerged (dry run protection of the rinsing
pump).
7. Fit the container cover.
Switching on the control system and additional units, checking the pipes
8. Switch on the control system and perform any necessary adjustments. (→ Operation)
9. Switch on the filter pump and UVC clarifier (if applicable).
– Ensure that the water is returned to the pond via the return pipe.
10. Check all pipes, hoses and their connections for leaks.
– Expansion seals may leak initially until they have fully expanded on contact with water.
11. Adjust the level detection device, if necessary. (→ Setting the level detection device)
It takes approx. 3 to 4 weeks before the micro-organisms in new filters are fully established.
During this time – or at a water temperature of <50 °F (<10 °C) – the filter may overflow. In this
case the filter does not need to be cleaned.
– When using filter starters, medicines or pond water treatments, leave the UVC clarifying
unit switched off for at least 36 hours so as not to impair their efficacy.
Setting the level detection device
A rise in the water level during operation indicates that the system is contaminated. The level detec-
tion device signals possible soiling to the control system and the cleaning cycle is started.
The water level in the filter system is independent of the water level in the pond. The water level in
the filter system depends on the circulation capacity. Therefore it may be necessary to adjust the
level detection device.
The level detection device can be fitted in two positions.
• Position 1: Suitable for circulation capacities greater than 3963 gph (15000 l/h) (factory default
setting).
• Position 2: Suitable for circulation capacities lower than 3963 gph (15000 l/h) and fewer automatic
cleaning intervals.
How to proceed:
1. Undo both lock nuts. Remove nuts and Allen screws.
2. Move the level detection device according to the hole pattern and fasten in place with Allen
screws and lock nuts. Tighten both nuts.
BTC0031