Setting the level detection device
Adjust the level detection device to the water level in the container to ensure the optimum operation
of the filter system. A 10 mm open jaw spanner is required for this adjustment.
How to proceed:
1. Remove the container cover.
– The filter drum is stopped for safety reasons if the filter cover is lifted and Er11 is indicated on
the display of the control system.
2. Switch off the filter pumps and check the water level.
– Ensure that the water level reaches the height of the maximum mark on the inside wall of the
container, at least above the Min. mark.
– Adjust the water level in the pond if necessary.
3. Switch off the voltage (ensure that the control system is isolated).
4. Undo both screws of the level detection device so that it can be easily moved.
5. Fit the container cover.
6. Switch on the control system and filter pumps and start a cleaning cycle.
7. Isolate the control system and remove the container cover.
8. Move the level detection device until the marking on the housing is at the same level as the water
level.
9. Tighten the two screws of the level detection device.
10. Replace the container cover and switch on the control system.
Please note:
– Make the setting quickly after the cleaning process. The screen elements continually trap
dirt particles. This causes the water level to drop in the container.
– Subsequently start a new cleaning cycle and check the setting. Correct the setting if neces-
sary.
– Check the setting again when the desired water quality has been reached.
ProfiClear0044