LipuJet - P -RB / - RD / - RM / - RA / - RAP
Installation
Assembly position right or left
Version on the right, example:
On-site inlet line from the right _ Inlet line
tank
Open the connection port
ventilation on the right [ 27 ] (cut open at
the notch and deburr the chamfer).
Seal the tank ventilation connection port
[ 29 ] with material provided by the
customer.
Version on the left is mirrored.
2.3.3 Baffle plate assembly
IMPORTANT
After installation, the open side
in the opposite direction to the direction of flow
the grease separator).
The two lower holes must be used for
size 15.
For nominal sizes 20 and 22.5, the two upper holes
used for fixing.
Tighten the screw joints by hand.
72/ 454
is at right angles to the axis of the
Numbers in brackets " [ ] ",
"Components".
for the tank
of the baffle plate must point
(inlet line of
fastening with nominal
Representation of the components _ Chap. 2.3.1
must be