1 – Defender of the direct circuit (Fig. U)
2 – in ioperation -aktiv- (Fig. U)
3 – triggered -close- (Fig. U)
11.3.5 Low oil level alarming system
Low oil pressure alarming system is designed to
prevent the engine being damaged by lack of
machine oil in the crankcase. Before the machine
oil in the crankcase declines to the security line,
the low oil pressure alarming system will turn off
the engine automatically. (The switch of the engine will be still in the "OPEN" position.)
After low oil pressure alarming system has closed the engine, if you operate the starter again, the
low oil pressure alarming light will lighten (Fig. V), and the engine will not run. If this happens,
please add machine oil.
11.4
Turn off the engine
Normal use:
1. Turn off all the installations that are
connected, and unplug the plug (Fig. W)
2. Turn the switch (Fig. X) of the plug to the
"OFF" position.
3. After the engine is totally cooled, turn the ventilating pole of the fuel-burning lid to the
"CLOSE" position counter-clockwise (Fig. Y).
12 MAINTENANCE
The purpose of making maintenance and
adjustment plan is to keep the generator in the
best working condition.
Please check and maintain the generator
according to the plan in the following chart.
Please turn off the engine before you carry out
any repair. If the engine needs to run when
repairing, make sure the operating area is well
ventilated, as the exhaust contains toxic CO.
ZIPPER MASCHINEN GmbH
ZI-STE2000IV
www.Zipper-Maschinen.at
The direct current socket can
be applied when you are
using alternating current.
Overloading direct circuit may
make the defender of the direct
current trip. (The pressed switch
springs back.) If this happens,
wait for a few minutes, and then
press the defender again to re-
operate.
I M P O R T A N T
If you want to stop the engine
urgently, turn the switch of the
engine to the "CLOSE" position.
A T T E N T I O N
Please use authentic
components of ZI-STE2000IV or
other substitutes with the same
quality.
The unqualified components will
damage the generator.
The plan chart for maintenance
MAINTENANCE
35