5. Clean Fuel Strainer (ONCE A MONTH)
The strainer of the fuel sump should be cleaned once a month and before starting
the heater at the beginning of each season.
(a)
Close the valve closest to the heater.
(b)
To catch the fuel which will drain out, set the Oil catch below the strainer
cover, with a small container under it.
(c)
Loosen the two screws from the Strainer cover and remove.
(d)
Remove the strainer and wash with fuel oil.
(e)
Return the strainer to its original position. Replace strainer cover and screw
to secure.
(f)
Wipe away any spilled fuel.
(g)
Open the valve in the fuel line. Check for fuel leakage.
NOTE: At the end of each season, unscrew the drain screw to remove all remaining fuel from the fuel sump.
6. Recommended Periodic Maintenance
As a state-of-the-art furnace, your heater requires periodic inspection and service by an authorized technician
to insure optimum, trouble free performance. This inspection should include: a combustion check; flue pipe
check; burner assembly check; cleaning all necessary parts and replacing gaskets as needed. Please ask your
authorized TOYOTOMI dealer for details and scheduling.
When the heater is on and clock is set (See SECTION E: OPERATION), it will automatically stop and clean the
igniter every day at 2:00 and will display "CL" on the digital indicator. After the cleaning mode is finished the heater
will automatically re-ignite and continue to burn again.
The igniter cleaning mode helps prolong the igniter life.
Heater will clean igniter for ten (10) minutes manually.
1. When ON/OFF switch is "OFF", press the "TIMER" button and "POWER SAVER" button at the same time for
more than three (3) seconds.
2. Display will appear "CL:10" on Display. Cleaning will begin and end without any additional input.
NOTE: Cleaning igniter is important to prolong igniter life. It is recommended that the igniter be cleaned once a
month if the time is not set.