Location of identification data on the appliance
The type designation and serial number can be found on
the type identification plate on the appliance. Make a note
of this data in your operating instructions and always refer
en

2 Description

2.1 Use of the product as directed
The appliance is designed to charge Hilti batteries of
the types PSA 80, PRA 82 and PRA 801 indoors, in dry
conditions.
The appliance is designed for use with the batteries
specified in these operating instructions. Use of this
appliance to charge batteries of other types is thus not
permissible.
Do not use the appliance where there is a risk of fire or
explosion.
Observe the information printed in the operating instruc-
tions concerning operation, care and maintenance.

3 Technical data

Right of technical changes reserved.
PUA 80 charger
Mains voltage
Mains frequency
Weight
Length of charger supply cord
Dimensions (LXWxH)
Control
Protection class
Operating temperature range
Storage temperature
Technical data for the
charger with the spe-
cified batteries
Max. output voltage
Max. output current
Charging times
Battery
Max. output voltage
Capacity
8
PRA 801
5.6 V
4.4 A
Approx. 2.5 h
PRA 801
3.6 V
8.5 Ah
to it when contacting your Hilti representative or service
center.
Type:
Serial no.:
The appliance is designed for professional use and may
be operated, serviced and maintained only by trained,
authorized personnel. This personnel must be informed
of any special hazards that may be encountered. The ap-
pliance and its ancillary equipment may present hazards
when used incorrectly by untrained personnel or when
used not as directed.
Tampering with or modification of the appliance is
not permissible.

2.2 Items supplied

1
PUA 80 charger
1
Supply cord
1
Operating instructions
100...240 V
50...60 Hz
0.36 kg (0.8 lb)
1.5 m (5 ft)
120 mm (4.7 in) x 58 mm (2.3 in) x 30 mm (1.2 in)
Electronic charging control (microcontroller)
Electrical protection class II (double insulated)
+0...+40°C (+32°F to +104°F)
-30...+60°C (-22°F to +140°F)
PSA 80
14 V
1.7 A
Approx. 1.5 h
PSA 80
9.6 V
2 Ah
PRA 82
3.8 V
4.4 A
Approx. 2.5 h
PRA 82
2.4 V
8 Ah