Electrical Connection; Function - Aventics HF03 Instrucciones De Servicio

Ocultar thumbs Ver también para HF03:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

50
AVENTICS | HF03/HF02 | 1987765472–BDL–001–AB
System architecture
Multiple plug connector I
Accessories
Valve blocks
Mit Fremdsteuerung!
Mit Fremdsteuerung!
With external pilot control!
With external pilot control!
A pilotage externe!
A pilotage externe!
Con pilotaggio esterno!
Con pilotaggio esterno!
¡Con pilotaje externo!
¡Con pilotaje externo!
Fig. 2:
Reference plate
on external pilot
control valve
systems
3.4

Electrical connection

Valve control
W
Mating plug I up to 8 or 16 valve positions
W
Modules can be plugged onto the multiple plug connector I:
– Bus coupler BDC type V-Design
PROFIBUS DP
INTERBUS
DeviceNet
CANopen
– Bus coupler BDC type A-Design
AS-Interface
– Bus coupler DDL type V-Design
DDL/DDL-E
3.5

Function

The valve system is connected to the pneumatic system via two
end plates (main and pilot air, air supply and exhaust air):
W
Channel 1 supplies all valves with compressed and pilot air.
W
The exhaust air from all main valves is removed through
channels 3 and 5. In the 3/2 valve units, the exhaust air from
connection 2 is removed through channel 3, and the exhaust
air from connection 4 through channel 5.
W
End plates for external pilot control: the valves are supplied
external pilot control air via connection X. Vital at a working
pressure of < 2.5 bar or during vacuum operation. External
pilot controlled valve blocks are identified by a reference
plate on the left end plate, see figure 2.
W
The pilot control valves are ventilated via channel R.