caused by the electrical motor within the compressor assembly;
during compressor start-up the sound level will be slightly higher
for a limited period of time.
caused by the cooling agent flowing through the circuit.
In addition, the side of the housing may become warm. This heat is caused by dissipation of the heat
generated inside the cabinet.
The following table lists the possible malfunctions, their probable causes and solutions. In the event
of operational problems, check first whether a solution can be found using this table. If the problem
persists, disconnect the appliance from the mains power and contact our Customer Service
Department.
Problem
The appliance does not
operate.
Abnormal noise can be
heard during operation.
Water accumulates on the
interior floor.
The temperature inside the
cabinet compartment is not
low enough.
The display shows „LL",
„HH" or „F1".
Transporting the appliance
The unit must be transported only in its vertical position.
Do not tilt it any more than 45°. During transport, ensure that the unit is properly secured and
protected against shock, vibration and shifting.
Disposal
This appliance has been manufactured from recyclable materials. After removing the plug
from the wall socket, the unit should be rendered unusable by cutting off the power cord
before being disposed of through special waste collection points in accordance with local
regulations. The refrigerant and the chemical agent in the insulation foam must be disposed of
through a competent agency. Take special care not to damage the cooling circuit before the unit is
handed over for competent disposal.
Possible cause and solution
Unit is not connected to the mains power.
The wall outlet has no power.
Either the unit has been improperly set up (e.g. on an uneven floor)
or there is contact between the rear-mounted cooling circuit and the
power cord, the wall or other object or surface. Verify that all
installation instructions in this manual have been correctly complied
with.
The melt-water drain system is blocked. Remove blockage and clean
drain system.
Check the temperature setting.
The door has been opened too often, or was left open.
The door is not closed properly.
The rubber seals in the door are not positioned correctly.
Insufficient space between the rear of the unit and the wall.
Call the service hotline.