Troubleshooting Guide; Backpack Battery - Stihl AR 2000 L Manual De Instrucciones

Ocultar thumbs Ver también para AR 2000 L:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

English

21 Troubleshooting Guide

21.1 Backpack Battery

Always disconnect the battery before carrying out any inspection, cleaning or maintenance.
Condition
LEDs and
Acoustic
Signals
Power tool does not
1 LED flashes
start when switched
green and six
on.
long beeps are
emitted.
1 LED glows
red.
4 LEDs flash
red and a rapid
succession of
short beeps is
emitted.
3 LEDs glow
red.
3 LEDs flash
red.
Power tool cuts out
1 LED glows
during operation.
red.
3 LEDs glow
red.
22
Cause
Remedy
Battery has low
► Charge the battery, @ 8.
charge.
Battery too hot / too
► Allow the battery to warm up or cool down gradually at
cold.
ambient temperatures of about 50 °F to 68 °F (10 °C to
20 °C).
Malfunction in
► Disconnect the battery from the power tool and reconnect it.
battery.
► Switch on the power tool.
► If the LEDs continue to flash, do not attempt to use the
battery.
The battery has a malfunction and must be replaced.
Power tool too hot.
► Allow the power tool to cool down.
Malfunction in power
► Disconnect the battery from the power tool and reconnect
tool.
the battery.
► Switch on the power tool.
► If the LEDs still flash, do not attempt to use the power tool.
The power tool has a malfunction and must be checked by
a servicing dealer.
Battery too hot / too
► Allow the power tool and battery to warm up/cool down
cold.
gradually at ambient temperatures of about 50 °F to 68 °F
(10 °C to 20 °C).
Power tool too hot.
No electrical contact
► Disconnect the battery from the power tool and reconnect it.
between power tool
► Switch on the power tool.
and battery.
► If the power tool still cuts out during operation, clean the
contact surfaces on the connecting cord, @ 19.2.
21 Troubleshooting Guide
0458-820-8621-A

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Ar 3000 l

Tabla de contenido