Cleaning and Maintenance
Before starting any cleaning or maintenance activities:
1.
Unplug the device's power cord from the outlet.
2.
Let the device cool down.
Cleaning
Make sure to empty the tank before cleaning.
Use normal glass cleaner and a soft cloth to wipe off the outside casing.
Clean the external optics with glass cleaner and a soft cloth every 20 days.
Always be sure to dry all parts completely before plugging the unit back in.
Cleaning frequency depends on the environment in which the unit operates (i.e. smoke, fog residue,
dust, dew).
Do not immerse the device in any liquid.
Maintenance
All screws should be tightened and free of corrosion.
The housing, the lenses, the mounting supports and the installation location (e.g. ceiling, suspension,
trussing) should not be deformed, modified or tampered with; e.g. do not drill extra holes in
mounting supports, do not change the location of the connections...
Mechanically moving parts must not show any signs of wear and tear.
The electric power supply cables must not show any damage. Have a qualified technician maintain
the device.
There are no user-serviceable parts, apart from the fuse and the lamp.
Refer to an authorized dealer for service and/or spare parts.
10.
Technical Specifications
power supply ......................................................................... 220-240 V~, 50/60 Hz
warm-up time............................................................................................... 3 min.
fluid consumption ............................................................................. 60-80 ml/min.
IP rating ........................................................................................................ IP20
options
high-density hazer liquid (5 L) ............................................................. VDLHLH5
HQHZ10001
power consumption .......................................................................................600 W
fuse ............................................................................................................... F5A
output .................................................................... ca. 170 m³/6,000 ft³ per minute
tank capacity ................................................................................................. 1.2 L
remote controller wire length.......................................................................... 3.5 m
dimensions .............................................................................. 320 x 170 x 220 mm
HQHZ10002
power consumption ..................................................................................... 1000 W
fuse ............................................................................................................... F6A
output .................................................................. ca. 225 m³/10,000 ft³ per minute
tank capacity ................................................................................................. 2.3 L
dimensions .............................................................................. 420 x 170 x 300 mm
Use this device with original accessories only. Velleman nv cannot be held responsible in the
event of damage or injury resulting from (incorrect) use of this device. For more info
concerning this product and the latest version of this manual, please visit our website
www.hqpower.eu. The information in this manual is subject to change without prior notice.
© COPYRIGHT NOTICE
The copyright to this manual is owned by Velleman nv. All worldwide rights reserved. No part
of this manual may be copied, reproduced, translated or reduced to any electronic medium or otherwise
without the prior written consent of the copyright holder.
V. 01 – 21/12/2015
HQHZ10001/HQHZ10002
10
©Velleman nv