6. Press the 4 key. The cursor will jump to the next field,
Drying time. Enter the desired value via the keypad or
the + and – keys.
7. Press the 4 key. The cursor will jump to the next field,
Pre-heating time. Enter the desired value via the key-
pad or the + and – keys.
8. Press the 4 key. The cursor will jump to the next field,
Vacuum. Enter the desired value via the keypad or the
+ and – keys.
9. Press the 4 key. The cursor will jump to the next field,
Vacuum time. Enter the desired value via the keypad or
the + and – keys.
10. Press the 4 key. The cursor will jump to the next field,
Firing time. Enter the desired value via the keypad or
the + and – keys.
11. Save your new program by pressing the S key.
12. To start the program, press the start stop key. The green
LED will be lit (see "Turning on the unit/Starting a firing
program"). The remaining firing time field indicates how
long the program still has to run.
Note: The following keys can be used while a program is
running:
(3) ÈÍ keys: Firing platform, (5) Menu key: Configuration
menu (parameters can be read but not modified),
(13) start stop key: stops the running program.
Controls 6
53
MultimatEasy