Malfunction
IPM module
temperature too high
protection
PFC module protection
DC fan motor failure
PFC module thermal
circuit is abnormal
PFC module high
temperature protection
Input power failure
8.
8.
8.
Troubleshooting
Troubleshooting
Troubleshooting
Error code
1. Output exception of IPM module
thermal circuit
EE15
2. Motor is abnormal or damaged
3. Fan blade is broken
1. Output exception of PFC module
2. Motor is abnormal or damaged
3. Fan blade is broken
EE16
4. Input voltage leap, input power is
abnormal
1. DC motor is damaged
EE17
2. Main board is damaged
3. The fan blade is stuck
EE18
The driver board is damaged
1. PFC module thermal circuit output
abnormal
2. Motor is abnormal or damaged
EE19
3. Fan blade is broken
4. The screw in the driver board is not
tight
EE20
The supply voltage fluctuates too much
Reason
- 44 -
Solution
1. Change a driver board
2. Check if the fan motor speed
is too low or fan motor damaged,
change it
3. Change the fan blade
1. Change a driver board
2. Check if the motor speed is
too low or fan motor damaged,
change it
3. Change the fan blade
4. Check the input voltage
1. Detect DC motor, replace with
a new one
2. Change a new main board
3. Find out the barrier and work
it out
1. Change a new driver board
2. Check if the fan motor speed is
too low or fan motor damaged,
change it
1. Change a new driver board
2. Check if the motor speed is
too low or fan motor damaged,
change it
3. Change the fan blade
4. Check if the screw is loose
Check whether the voltage is
stable