5.4 Initial operation

After all connections have been made and checked, carry out the following procedure:
1.
Switch on the filtration pump. Check for leaks and verify that water is flowing to and from the swimming pool.
2.
Connect power to the heat pump and press the On/Off button
The unit will start up after the time delay expires (see below).
3.
After a few minutes, check whether the air blowing out of the unit iscooler.
4.
When the filtration pump is turned off, the unit should also turn off automatically.
5.
Allow the heat pump and the filtration pump to run 24 hours a day until the desired water temperature is
reached. The heat pump will stop running at this point +1°C. After this, it will restart automatically (as long as
the filtration pump is running) whenever the swimming pool water temperature drops 1 degree below the set
temperature (for example, if you set the temperature 28°C, the heat pump will stop when the temperature at
29°C. While it will restart when the temperature of the water down to 27°C)
Depending on the initial temperature of the water in the swimming pool and the air temperature, it may take
several days to heat the water to the desired temperature. A good swimming pool cover can dramatically
reduce the required length of time.
NOTE
Water Flow Switch:
It is equipped with a flow switch for protecting the HP unit running with adequate water flow rate. It will turn
on when the filtration pump runs and shut it off when the pump shuts off.
Time delay - The heat pump has a built-in 3-minute start-up delay to protect the circuitry and avoid excessive
electrical contactor wear. The unit will restart automatically after this time delay expires. Even a brief power
interruption will trigger this time delay and prevent the unit from restarting immediately. Additional power
interruptions during this delay period do not affect the 3-minute duration of the delay.