Vimar ELVOX RS06 Manual De Instrucciones Para La Conexión Y El Uso página 29

Central con pantalla de 24 vdc para cancela corredera
Ocultar thumbs Ver también para ELVOX RS06:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 74
4.2- Wiring for flashing light, courtesy light and gate movement warning light
N.B.: Do not change the motor output wiring (terminals 1 and 2) the dip switch 2-2 selects the direction of opening.
Terminals
Description
1-2
Motor output
3-4
Courtesy light or second radio channel
4-5
Warning light output
6-7
Accessories power supply output
8-9
Output for flashing light
Input description table:
The control unit is supplied with jumpered normally closed inputs (stop, photo and stpa) remove the jumper from the input you are going to use.
CN2
10 11 12 13 14 15 16
EN
-
+
-
+
white
M
Electric
Accessories power supply
motor
output 24V dc 300mA
24 Vdc 65 mA max
24 Vdc 65 mA max
Courtesy light or
gate
movement
warning light
second radio channel
Terminal number
10-13-18
Sequential control input, to govern the complete travel of
11
Sequential control input, to govern the pedestrian travel
12
14
15
Photocell input, active during closing
Input for edges or internal photocell, active during
16
Opening limit switch input with parameter 31 OFF
17
Closing limit switch input with parameter 31 ON
Closing limit switch input with parameter 31 OFF
19
Opening limit switch input with parameter 31 ON
-
-
+
24 Vdc 15 W max
Function
Output for controlling electric motor 24 V dc rated power 50 W
(terminal number 1 white, terminal number 2 brown)
Output 24 V dc maximum load 65 mA, can be programmed as a timed output (60
seconds) or second radio channel output (3 = GND / 4 = +24 V dc).
Output 24 V dc maximum load 65 mA, flashes slowly when opening, on with station-
ary open gate, flashing fast when closing and off with gate closed (4= 24 V dc / 5=
GND).
Output 24 V dc maximum 300 mA for supplying the photocells
(6 = +24 Vdc, 7= GND)
Output 24 V dc maximum load 15 W for flashing light (8 = GND, 9 = + 24 V dc).
Description
Control inputs common
(permanent GND)
the gate
of the gate
Input for stopping the gate
gate closing and opening
Fig. 5
Input type
-
Normally open
Normally open
Normally closed
Normally closed
Configurable: normally closed or
balanced at 8.2 K ohm
Normally closed
Normally closed
27
27

Publicidad

Tabla de contenido
loading

Tabla de contenido