Vimar ELVOX RS06 Manual De Instrucciones Para La Conexión Y El Uso página 34

Central con pantalla de 24 vdc para cancela corredera
Ocultar thumbs Ver también para ELVOX RS06:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 74
6.1- Procedure for facilitated gate travel programming:
Starting with the closing limit switch engaged (gate closed), after entering programming mode by pressing the UP, OK, and AP/CH button, the gate starts
opening at reduced speed until the opening limit switch is engaged. After 2 seconds the gate starts closing at cycle speed and slows down approximately
50cm from being completely closed and continues until the closing limit switch is engaged. The control panel saves the gate travel, with default deceleration
speed and distances,
32 32
1
The gate goes into the fully
open position and slow
speed
The control panel saves the
CLOSING
2
The gate closes
Continues closing at re-
at cycle speed
duced speed until complete-
values and exits the
programming mode
3
ly closed