4.6- Connecting sensitive edge or internal photocell
With edge or photocell not engaged the STPA LED must be on, see parameter 6. If not used, jumper
between COM and STPA. If a switch sensitive edge is connected, parameter 6 must be set to 2 and when connecting a resistive sensitive edge set parameter
6 to 3 (the edge tripping during opening reverses the movement of the gate by approximately 10 cm whereas during closing it causes total opening).
4.6.1 Resistive sensitive edge connection
4.6.2 Connecting internal photocell
If the STPA input is connected to the photocell receiver, set parameter 6 to 1, default setting (if the internal photocell is engaged the gate will stop, both when
opening and when closing, and then it will remain stationary until the photocell is freed, to then start again with opening).