IT-GB-FR-ES mod. 505
EMERGENCY CONTROLBOARD PUSH BUTTONS FUNCTION
Button 3
- Switch ON and Switch Off.
Radio symbol
- Indicates the radio communication with the radiocontrol
Alarm symbol
- Indicates an alarm on the appliance.
Button 2
- Increases the working power of the appliance.
Button 1
- Reduces the working power of the appliance.
REGULATION of the Power of the appliance.
The appliance has the possibility to be regulated within a range of 5 power levels (1-min, 5-
max), during the first working hours we suggest to put the power regulation on level 3.
The appliance will use the selected power value as maximum value for the function of heating
of the plant, in this way it is possible to restrict the max. power of the appliance.
In any case if the selected power permits to temperature to reach the selected value,
the appliance will automatically reduce the power (modulation) in order to reduce
the consumption of the fuel.
- By mean of the radiocontrol, out of any menu press on button 5
- Regulate the power of the appliance utilizing the buttons 1 e 2
-Terminate the regulation of the power pressing shortly on button 5, the
modification will be confirmed and the radiocontrol returns to the
previous indication
SELECTION of Room temp. feeler.
It is possible to select in which way you want to take the room temperature. It is possible to
take the temperature by mean of the feeler put on the back of the appliance or by mean of the
feeler put on the radiocontrol. In case you select to use the feeler put on the radiocontrol, pay
attention to the place where it is put.
- By mean of the radiocontrol, out of any menu press on button 7
- Press on button 5 until you reach MENU 05
- Press on button 7 (menu) to enter into MENU05
- With button 1 and 2 select the type of room
feeler (REMCONTR/INTERNAL)
- Terminate the selection pressing shortly twice
on button 3
If you intend to use the feeler on the
radiocontrol, we suggest to fix the support of the
radiocontrol in the coolest place of the room.
49/128