REGULATION of the Room Temperature
The setting of the room temperature means to put a limit to the heating process of the
appliance, whenever the room temperature exceeds the selected value (i.e. 20°C) the
appliance reduces automatically the power commuting on minimum (power 1)
- By mean of the radiocontrol, out of any menu press on button 4
- Regulate the desired temperature utilizing the buttons 1 e 2
- Terminate the regulation of the room temperature pressing shortly on
button 4, the modification will be confirmed and the radiocontrol returns to
the previous indication.
STARTING CYCLE
1st Lighting (new stove and whenever the pellet container has been completely emptied
-Put the fuel into the container and switch on the appliance
-In case the display is signalling an alarm keep the push button
3 pressed
-In case the display is signalling "Final cleaning" wait until on the display
appears "Off" (approx. 15 minutes)
-Appliance in switched off condition display "OFF"
-Press on push button 7 (menu) to get access to the programmation menu.
-Press on push button 5 to go on MENU 08
-Press on push button 1 to activate the continuous charge of fuel.
- Once the pellet has started to fall into the burner basket press on push
button 3 to stop the fall of fuel into the burner basket.
-Empty the burner basket from the fuel and put it again in its correct
place.
-Press the push button 3 and keep it pressed for few seconds until the
display reports the start of the lighting.
NORMAL STARTING CYCLE
Press the push button 3 and keep it pressed for few seconds
The appliance begins an automatic cycle to effect the lighting, this cycle is
composed by 3 phases, which are shown on the display of the radiocontrol:
1-START (duration approx. 2min.)
(lighting element heating)
2-LOAD PELLET (max. duration 18/20 min)
(fuel loading)
50/128
IT-GB-FR-ES mod. 505