2.3

POWER SUPPLY OPERATION AND TRANSPORT

SAFETY: WELDING HELMET – GLOVES – HIGH ARCH
SHOES/HIGH SHOES.
Transfer of the source is easy. The machine can be lifted, trans-
ferred and operated easily. However, the following instructions
have to be observed:
1.
Always remove the supply and welding cables prior to lifting
or transfer of the equipment.
2.
Never pull the welder by means of the supply and welding ca-
ble.
3.
You may transfer the generator by means of handles and
wheels or by means of lifting device.
4.
Observe safety instructions by lifting of the generator.
2.4

GENERATOR POSITION

ATTENTION: THERE MAY BE A SPECIAL INSTALLATION
ALSO IN THE PREMISES REQUIRED WHERE COMBUSTIBLE
LIQUIDS OR OTHER DANGEROUS MATERIALS ARE
PLACED.
Prior to placement of the generator please read the following in-
structions:
1.
The operator has to have a free access to the control panel
and to welding cables
2.
Use performance nameplate for the designation of a proper
place of the connection to the supply network.
3.
Do not place the generator into closed places. The generator
aeration is extremely important for a faultless operation.
Make sure the fan is not blocked. Entrance and exit holes for
the cooling air have to be completely free.
Make sure the generator does not suck absorbable materials,
mainly metal dust which may cause damage to the source.
2.5
GENERATOR MAKE-READY FOR WELDING WITH
COVERED ELECTRODE.
Attach all accessories by means of the following instructions:
1.
Attach the grounding cable to the minus (-) pole. Make sure
the cable is appropriately dimensioned for the required per-
formance. Attach grounding clamp near the weldment.
2.
Attach the welding cable to the plus (+) pole of the welder.
Place an appropriate electrode into the welding clamp.
IMPORTANT: CERTAIN ELECTRODES REQUIRE REVERSE
POLARITY. IN THAT CASE PLEASE CHANGE THE POLARITY
OF THE WELDING CABLES.
INSTALLATION
3.
Switch on the equipment and select the MMA function on the
switch.
NOTE: THE GENERATOR IS SUITABLE FOR GOUGING IN
THIS SETTING (ARC AIR). THE PROCEDURE OF CONNEC-
TION OF THE GOUGING TORCH IS THE SAME AS BY WELD-
ING BY A COVERED ELECTRODE. FOR GOUGING IT IS
NECESSARY TO USE A SUITABLE GOUGING TORCH.
PLEASE CONTACT YOUR DEALER.
Switch on the generator and set the required current value which
will be displayed on the display unit.
2.6
GENERATOR MAKE-READY FOR WELDING WITH
TUNGSTEN ELECTRODE (TIG)
1.
Attach the grounding cable to the plus (+) pole. Make sure
the cable is appropriately dimensioned for the required per-
formance. Attach grounding clamp near the weldment.
2.
Attach the welding cable to the minus (-) pole of the welder.
3.
Attach a suitable torch to the gas tank by means of a reduc-
tion valve.
4.
Switch on the welder and on the front panel set the tig sym-
bol.
5.
Start welding.
IMPORTANT: THE WELDING SEAM QUALITY MAY BE INFLU-
ENCED BY A STRONG EXHAUSTION AND AERATION OF
THE PREMISES. SHIELDING GAS MAY BE LESS EFFECTIVE!
2.7
GENERATOR MAKE-READY FOR WELDING IN
SHIELDING GAS (MIG/MAG)
1.
Attach the grounding cable to the minus (-) pole. Make sure
the cable is appropriately dimensioned for the required per-
formance. Attach grounding clamp near the weldment.
2.
Attach DEVID ARC (DV44) wire feeder according to the feed-
er manual. Attach the torch to the gas tank by means of a re-
duction valve.
3.
Switch on the welder and set CV/CC on the front panel
4.
Start welding
2.8
42V POSITION
1.
This generator selection serves for the supply of constant
42V DC voltage max. 150A.
2.
This voltage is present at welding clamps of the generator
IMPORTANT: THIS FUNCTION HAS OVERLOAD PROTEC-
TION.
2.9

REMOTE CONTROL ACTIVATION.

The remote control serves for the generator control from larger
distances. The remote control cable length may be even 50m
long. Activation:
1.
Switch on the generator.
2.
Select the required type of welding.
3.
Set the required maximum value of the welding performance
on the generator.
4.
Mount the remote control plug. The welder automatically de-
tects the presence of the remote control. This condition is in-
dicated by led 2. By means of a potentiometer you may set
4 EN
EN