Technical Data - DITEC Rex Serie Manual De Instalacion Y Manutencion

Puertas correderas
Ocultar thumbs Ver también para Rex Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 26
1.

TECHNICAL DATA

GB
Power supply
Absorption
Accessories power supply
Opening speed
(max.)
Closing speed
(max.)
Acquisition speed (max.)
Intermittence
Max run
Max. door weight
Temperature
Degree of protection
2.
REFERENCE TO ILLUSTRATIONS
The given operating and performance features can only be guar-
anteed with the use of DITEC accessories and safety devices.
2.1 STANDARD INSTALLATION REFERENCES (fig. 1)
[1]
Electrical Board
[2]
Geared motor
[3]
Radar
[4]
Release
[5]
Photocells
[6]
Selector
[7]
Capacitor
[8]
Connect power supply to a type-approved omnipolar
switch with a contact opening gap of no less that 3 mm
(not supplied by us) protected against accidental and
unauthorized activation.
Connection to supply mains must be carried out in an
independent raceway separate from control connections
and safety device connections.
2.2 AUTOMATION REFERENCES (fig. 2)
[9]
Opening/Closing stops
[10] Lock
[11] Batteries kit
[12] Transmission unit
[13] Belt
[14] Guide
3.
INSTALLATION
Unless otherwise specified, all measurements are expressed
in millimetres (mm)
3.1 FIXING GUIDE
Fig. 3-4 shows the fastening of the guide [14] in accordance with
the height of the wing:
HM = height of framed mobile wing;
HVM = height of glass on mobile wing;
-
Fasten guide by means of steel blocks M6 Ø12 or screws
6MA. The point of fixing shall be set on the guide around
every 800 mm.
-
Verify if guide [14] rear side is perpendicular to the floor
and not lengthwise deformed by the shape of wall. Should
the wall not be straight and smooth, iron plates shall be
arranged on it prior to guide fastening.
WARNING: the housign must be attached securely to the
wall to support the weight of the wings.
REX - IP1838
REX1
230V~50-60 Hz
0,5 A
24 V= / 0,3 A (192C) 0,5 A (EL16)
0,5 m/s (192C) 0,1÷0,6 m/s (EL16)
0,35 m/s (192C) 0,1÷0,6 m/s (EL16)
0,1 m/s
S3 = 100%
3500 mm
100 kg
-10° C/ +50°
IP20
12
24 V= / 0,3 A (192C) 0,5 A (EL16)
1 m/s (192C) 0,2÷1,2 m/s (EL16)
0,7 m/s (192C) 0,2÷1,2 m/s (EL16)
3.2 FRAMED DOOR WING PREPARATION
The door must be robustly constructed and its glasses must
be glued at least at the corners. The upper transom must be
reinforced on the inside with an iron profile on which the su-
spension profile must be screwed on several points. For tall,
narrow wings, the steel reinforcement must extend over part of
the vertical uprights. It is advisable to install rubber borders at
the ends of the wing to reduce force of impact.
3.3 CRYSTAL DOOR PREPARATION
(Fig. 5) The AC1356 crystal fitting section may be used with
crystal-only wings of 10 or 12 mm thickness.
It is not usable on any kind of normal or stratified glass.
The blocking operation is to be carried out through holes Ø 10,
present on aluminium profile, and holes Ø 15, present on the
glass. Number of holes and relative distance between centres
depend on door wing width. We recommend to apply a light layer
of silicone between the glass corner and the end of the profile.
Crystal door wing references
[A]
Square washer
[B]
Screw M6 TPS
[C]
Threaded panel
[D]
Nylon bush for 10 mm crystal
[E]
Nylon bush for 12 mm crystal
3.4 DOOR WING INSTALLATION AND ADJUST-
MENT
-
Mount the door wing to the wheel unit by means of
screws [J]. The outside wheel of the wheel unit shall not
be projected from the door wing.
-
Adjust the horizontal position of the wing respecting
the measurements shown in figs 6, 7 and 8 and set the
adjustment with screws [J].
-
Loosen screws [K], adjust the vertical position of the wing
with screw [M] and set the adjustment with screws [K].
NOTE: Check, by moving the wing by hand, that it moves freely
and without friction and that all the wheels bear on the guide.
If necessary loosen the screws [J] and [K], adjust the carriages
onto the guide and tighten the screws.
REX2
230V~50-60 Hz
0,5 A
0,2 m/s
S3 = 100%
3500 mm
140 kg
-10° C/ +50° C
IP20

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Rex1Rex2

Tabla de contenido