GENERAL SAFETY PRECAUTIONS
GB
This installation manual is intended for professionaly compe-
tent personnel only.
The installation, the electrical connections and the settings
must be completed in conformity with good workmanship and
with the laws in force. Read the instructions carefully before
beginning to install the product. Incorrect installation may be
a source of danger.
Packaging materials (plastics, polystyrene, etc) must not be
allowed to litter the environment and must be kept out of the
reach of children for whom they may be a source of danger.
Before beginning the installation check that the product is in
perfect condition.
Do not install the product in explosive areas and atmosphe-
res: the presence of flammable gas or fumes represents a
serious threat to safety. The safety devices (photoelectric cells,
mechanical obstruction sensor, emergency stop, etc) must be
installed taking into account: the provisions and the directives
in force, good workmanship criteria, the installation area, the
funtional logic of the system and the forces developed by the
motorised door or gate.
Before connecting to the mains check that the rating is correct
for the destination power requirements.
A multipolar isolation switch with minimum contact gaps of 3
mm must be included in the mains supply.
Check that upstream of the electrical installation there is an
adequate differential switch and a suitable circuit breaker.
When requested, connect the motorized door or gate to an
effective earthing system carried out as indicated by current
safety standards. During installation, maintenance and repair
operations, cut off the power supply before opening the cover
to access the electrical parts.
The electronic parts must be handled using earthed antistatic
conductive arms. The manufacturer of the motorising device
declines all responsability in cases where components which
are incompatible with the safe and correct operation of the
product only original spare parts must be used. For repairs
TECHNICAL DATA
Power supply
Absorption
Motor output
Safety accessories power supply
Temperature
Degree of protection
Dimensions
0906 - IP1443
or replacements of products only original spare parts must
be used. The fitter must supply all information corcerning the
automatic, the manual and emergency operation of the moto-
rised door or gate, and must provide the user the device with
the operating instructions. It is recommended that antistatic
conductive earthed arm bands be worn when manipulating
electronic parts
INSTALLATION WARNING
Secure the electric board permanently. Drill the lower side of
the container so as to run the cables through it. Secure the
cables, if they are accessible, by means of appropriate gland
plates (not provided by us). Keep the line conductors separate
(at least 8 mm.) from the control conductors and motor at the
terminal board connection points (for example, by means of
clamps). Re-close the container by means of the 4 screws.
230 V~ / 50-60 Hz
1 A
24 V=
6x2 A max
24 V= / 0,5 A
-20° C / +55° C
IP55
225x320x120
4