Master / Slave Mode; Operation With A Dmx Controller; Setting The Number Of Dmx Channels And The Start Address; Using Subaddresses - IMG STAGELINE ODB-1212RGBW Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 34

4.3 Master / slave mode

Multiple ODB-1212RGBW can be operated
in sync; in this mode, one unit (master unit)
will control the other units (slave units).
1) Connect the units in a chain, as de -
scribed in chapter 3.2.2.
2) At the master unit, select the menu item
MASTER
with the button M,
OFF
When
appears on the second line,
ON
go to
:
a) Press the button
and go to
L
M
the button
or
.
b) Confirm with the button
3) At the master unit, activate the operat -
PROGRAM
COLOUR
ing mode
or
ter 4.1).
4) Set all slave units to the slave mode:
RUN MODE
a) Select the menu item
Note: The display will flash as long as the
slave units do not receive any control sig-
nals from the master unit.
DMX
b) If
appears on the second line,
press the button
and go to
L
M
with the button
or
c) Confirm the setting with the button

4.4 Operation with a DMX controller

For operation by means of a DMX light con-
troller (e. g. DMX-1440 or DMX-510USB
from "img Stage Line"), the LED light effect
bar is equipped with 59 DMX control chan-
nels. However, it can also be controlled by
11, 8, 5, 4 or 3 channels if the functions pro-
vided by these channels suffice (see chap-
ter 5.1) or if less than 59 channels are avail-
able at the light controller.
DMX stands for Digital Multiplex and
means digital control of multiple DMX units
via a common control line.
CUSTOM12
Pro12
CUSTOM12
M
CUSTOM12
Pro01

Creating user-defined show programs
4.4.1 Setting the number of DMX channels
and the start address
For separate control of all DMX units con-
nected to the light controller, each unit
requires a start address of its own. Exam-
ple: If the first DMX channel of the ODB-
1212RGBW is to be controlled by the light
controller via DMX address 6, set the start
L
M
or
.
address on the ODB-1212RGBW to 6.
The other DMX channels of the ODB-
1212RGBW will then be automatically
ON
with
assigned to the subsequent addresses.
Examples for various start addresses:
.
Number
of DMX
Start
(chap -
chan-
address
nels
3
.
4
5
SLAVE
8
.
.
11
59

DMX address assignment of the
ODB-1212RGBW
1) Select the menu item
the button M,
2) Press the button
DMX channels (
ing.
3) Set the number of the channels desired
with the button
4) Confirm the setting with the button
The DMX start address (
start flashing.
5) Set the address with the button
and then confirm with the button
indication will stop flashing. Set the
LED :01
STRO:00
LED :01
STRO:00
FADE:00
TIME:00
EDIT
Sce32
M
M
EDIT
Sce01
FADE:00
TIME:00
Addresses
Next possible
used by
start address for
the ODB-
the subsequent
1212RGBW
DMX unit
1
1 – 3
4
6
6 – 8
9
1
1 – 4
5
6
6 – 9
10
1
1 – 5
6
12
12 – 16
17
1
1 – 8
9
56
56 – 63
64
1
1 – 11
12
502
502 – 512
1
1 – 59
60
60
60 – 118
119
DMXSETUP
L
M
or
.
: The number of
CH:..
) will start flash-
L
M
or
.
A:...
L
LED
12
STRO:00
M
M
LED
01
STRO:00
LED :01
STRO 99
M
LED :01
STRO 00
FADE 99
TIME:00
M
FADE 00
TIME:00
FADE:00
TIME 99
M
FADE:00
TIME 00
same address for all additional ODB-
1212RGBW that are to be controlled in
sync.
6) The LED bar can only be operated via
the DMX controller when the menu item
DMXSETUP
RUN MODE
or
the display. For
be shown on the second line; if required,
press the button
L
M
button
or
and then confirm with the
button
.
If there is no DMX control signal, the
display will start flashing as an indica-
tion.

4.4.2 Using subaddresses

In the 11-channel mode and in the 59-
channel mode, subaddresses may be used
to independently control up to 66 ODB-
1212RGBW one after the other via a single
DMX start address. Thus, the maximum
number of DMX units possible is substan-
tially increased. The last DMX channel (11
or 59) is used to select units with a subad-
dress. Units having the same start address
and different subaddresses may be con-
trolled in sync if DMX channel 11 or 59 is
set to a DMX value less than 10.
1) Select the menu item
L
the button M,
2) Press the button
with
will start flashing:
OFF
= no subaddress (DMX channel 11
or 59 not used and available for
other units)
01
66 =
...
subaddress set
L
3) Use the button
.
or to deactivate the function.
) will
4) To operate the LED bar: At the light con-
troller, set the DMX channel 11 or 59 to
M
or
the DMX value that corresponds to the
. The
subaddress of the LED bar (
5.1.1).
R:000
G:000
R:000
x:000
G:000
x 255
M
B:000
x:000
W:000
x 000
B:000
Menu item
W:000
Pro
Sce
LED
R, G, B, W
STRO
FADE
TIME
* Note: The length of scene must at least
be set to 001 (= 0.8 sec. approx.), other-
wise, the subsequent scene number
cannot be selected.
is shown on
RUN MODE, DMX
must
DMX
, go to
with the
SETUP ID
with
M
or
.
: The current setting
M
or
to set the address
chapter
Function
No. of show program
No. of scene
No. of LED
Colour brightness
Stroboscope frequency
Crossfading time
Length of scene*
13

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

38.7060

Tabla de contenido