Conventions in this document

For safe operation according to BVS 13 ATEX G 001 X and
PFG 14 G 001 X the instrument must remain in default alarm
settings as listed below.
– The relays must be set to Normally energ. and the A2
alarm (main alarm) must be set to Latching and Non-
acknowledgeable or Pre-Acknowledgeable.
– The A1 alarm (pre alarm) may only be set to
Acknowledgeable when it is used for triggering an
acoustic alarm device.
1.5.1 Calibration
– For proper operation, never adjust the span before
completing zero adjustment. Performing these operations
out of order will cause the calibration to be faulty.
– If the intended operation is at high altitudes, the reading
will be lower than the reading at sea level (reduced partial
pressure). A new span calibration is recommended if the
altitude or the ambient pressure is changed. The factory
calibration is set to sea level.
– Dräger recommends calibrating instruments with target
gas. This method is more accurate than a surrogate gas
calibration. A surrogate gas calibration may only be
performed as an alternative if a target gas calibration is
not possible.
– Methane and hydrogen should be calibrated with target
gas only and not calibrated with a surrogate gas.
®
For Polytron
8310 IR:
– The user must also read the Instructions for Use for
DrägerSensor IR, part number 9023981
1.6

During operation

– After modifying parameters with the PolySoft PC software
or another software, verify all parameters by downloading
from the instrument or by checking them on the Polytron
8xx0.
– IP ratings do not imply that the equipment detects gas
during and after exposure to those conditions. In case of
dust deposits and submersion/jet water, check the
calibration and the proper functioning of the device.
Risk of ignition of flammable or explosive atmospheres!
– CAUTION: High off scale readings may indicate an
explosive concentration.
(Only for instruments measuring combustible
atmospheres.)
– WARNING: Do not open when energized
®
Polytron
8100 EC-specific:
Response time t20 can exceed the limits of EN 50104 for
small concentration changes.
1.6.1 Maintenance
– The maintenance intervals must be established for each
individual installation. Depending on safety considerations
and application specific conditions the instrument is used
in, these might need to be shortened.
– Refer to the maintenance section in the transmitter
instructions for use.
2
Conventions in this document
2.1

Meaning of the warnings

The following warnings are used in this document to alert the
user to potential dangers. A definition of the meaning of each
warning is as follows:
Alert icon Signal word
WARNING
CAUTION
NOTICE
2.2

Typographical conventions

Text
Texts in bold type identifies labels on the device
and screen texts.
This triangle indicates the possibilities for avoiding
the hazard in warnings.
>
The greater-than sign indicates a navigation path
in a menu.
This symbol indicates information that facilitates
the use of the product.
®
2.3

Trademarks

Trademark
®
Polytron
®
DrägerSensor
®
PROFIBUS
®
HART
TM
FOUNDATION
The following webpage lists the countries in which Dräger's
trademarks are registered: www.draeger.com/trademarks.
3
Description
3.1

Product overview

Refer to the figures on the fold-out page
A 1
Enclosure lid
A 2
Set screw (2 mm Allen screw)
Warning classification
Indicates a potentially hazard-
ous situation. If not avoided, it
could result in death or serious
injury.
Indicates a potentially hazard-
ous situation. If not avoided, it
could result in physical injury. It
may also be used to alert
against unsafe practices.
Indicates a potentially hazard-
ous situation. If not avoided, it
could result in damage to the
product or environment.
Trademark owner
Dräger
Dräger
PROFIBUS Nutzerorganisation e. V.
HART Communication Foundation
Fieldbus Foundation
®
Dräger Polytron
8000 Series